DIME Sample ID 2025-01-31-28

Project Information

Project IdentifiersProject ID: 994084
DEA: 060U8804
EFIS: 0616000074
DIST-CO-RTE-PM06-TUL-99-26.3/27.6
Award Date01/23/2023
Closeout DateNot set
Work DescriptionCONSTRUCT A NEW INTERCHANGE AT COMMERCIAL AVENUE NOW CALLED INTERNATIONAL AGRI-CENTER WAY
Location DescriptionON STATE ROUTE 99
QA Service Level1 (Verified on 03/13/2023)

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

Sample Information

Sample Taken Date01/31/2025 Sample Unique Key28
Date that the sample was received by the laboratory/organization performing the testing02/18/2025 Sample typeQuality Assurance
A brief description of the sample#14 Dayton Couplers The quantity of what the sample constitutes54
From where was the sample collectedManufacturer First name of sampler or witnessed byTanya
Last name of sampler or witnessed byS Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameNucor Dayton Superior
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerNUCOR
Coupler ManufacturerDayton Superior Intermediate Assembler or Fabricator
Rebar Size#14 Coupler ModelD310 Taper Lock
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)6449 Rebar Heat Number(s)3500036691
Rebar Size 2 Coupler Unique IDST-17-11

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2025-01-31-28-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Steven Paine, CT HQ - Sacramento Structural Materials Testing Laboratory02/25/202502/25/2025
Yes
02/25/2025Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
COVER SHEET TM5 Couplers rev 2025-01-31-28pdf02/20/2025   Info
20235911.002A_20250131_25-SAC-00115_Metal_DIME ID# 2025-01-31-28pdf02/20/2025   Info

Test File Attachments


DIME Test ID: 2025-01-31-28-1 CTM 670-December 2013 (Verified)