Sample Record

DIME Sample ID 2017-05-09-7

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 210963
DEA: 120N78U4
EFIS: 1215000036
DIST-CO-RTE-PM12-ORA-5,22,57,73,133,405,etc.-VARIOUS
Award Date03/08/2016
Closeout Date06/21/2021
Work DescriptionINSTALL HD CCTVS AND MODIFY COMMUNICATION SYSTEM.
Location DescriptionINSTALL HD CCTVS AND MODIFY COMMUNICATION SYSTEM.
QA Service Level1 (Verified on 08/15/2016)

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

Sample Information

Sample Taken Date05/09/2017 Sample Unique Key7
Date that the sample was received by the laboratory/organization performing the testing05/11/2017 Sample typeQuality Assurance
A brief description of the sampleFlash Welded Rebar Hoops The quantity of what the sample constitutes4
From where was the sample collectedFabricator First name of sampler or witnessed byDavid
Last name of sampler or witnessed byGray Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameTNT Rebar
Transportation Laboratory (TL) NumberC720069 Inspector Lot Number from the Transportation Laboratory (TL) FormS3203217
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)4049973
Hoop Manufacturer Lot Number(s)1 Material Standard CodeASTM A706
Material Grade60 Rebar Size4
Diameter of Hoop2'-2" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCMC Rebar
Welding CompanyTNT Rebar Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2017-05-09-7-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory05/11/201705/11/2017
Yes
05/19/2017Bar Broke; OK NeckingPublic - Test Data Visible
2017-05-09-7-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory05/11/201705/11/2017
Yes
05/19/2017Bar Broke; OK NeckingPublic - Test Data Visible
2017-05-09-7-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory05/11/201705/11/2017
Yes
05/19/2017Bar Broke; OK NeckingPublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2017-05-09-7-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-05-09-7-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-05-09-7-3 CTM 670-December 2013 (Verified)