Sample Record
Owner Labs
- Twining, Incorporated - Long Beach
- Krazan & Associates
DIME Sample ID 2024-08-13-170
Project Information
| Project Identifiers | Project ID: 994109 DEA: 060W1704 EFIS: 0617000103 |
|---|---|
| DIST-CO-RTE-PM | 06-FRE-41-R27.4/R28.5 |
| Award Date | 11/08/2022 |
| Closeout Date | Not set |
| Work Description | REMOVE AC PAVEMENT, WIDEN TRAVEL WAY, AND CONSTRUCT RETAINING WALL. |
| Location Description | FRESNO COUNTY IN FRESNO FROM 0.1 MILE SOUTH OF ASHLAN AVENUE OVERCROSSING TO SHAW AVENUE OVERCROSSING |
| QA Service Level | 1 (Verified on 07/13/2022) |
Sample Information
| Sample Taken Date | 08/13/2024 | Sample Unique Key | 170 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 10/07/2024 |
| Sample type | Quality Control | A brief description of the sample | Concrete Thermal Expansion |
| The quantity of what the sample constitutes | two concrete cores | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Brett | Last name of sampler or witnessed by | Thornton |
| Title of sampler | Special Inspector | Telephone number of sampler | 5593482200 |
| Laboratory sample identification | CH24-318,CH24-319 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Builders Concrete Ready Mix Plant Sanger | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | 6-2 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | ND15518C |
|---|---|---|---|
| The truck number from where the sample was collected | 9116 | The batch plant ticket number from where the sample was collected | 111347786 |
| Concrete batch plant | Builders Concrete | The fabricator/manufacturer designation for the sample | concrete |
| A detailed description of where the material sample was collected | Rte 41 NB Ashlan on Ramp | Where the material sample would have been placed if not sampled | |
| From Lot No. | Bag Lot No. |
Submitted Tests
| DIME Test ID | Test Method | Tester Name, Testing Lab | Date Tested | Date Added | Verified? | Release Date | Test Comments | Privacy Level | Actions |
|---|---|---|---|---|---|---|---|---|---|
| 2024-08-13-170-1 | AASHTO T336-15: Standard Method of Test for Coefficient of Thermal Expansion of Hydraulic Cement Concrete | R. Davenport, Krazan & Associates | 10/10/2024 | 12/20/2024 | No |
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| 06-0W1704 COTE-10.25.2024 | 12/20/2024 | Info |
Test File Attachments
DIME Test ID: 2024-08-13-170-1 AASHTO T336-15