Sample Record

DIME Sample ID 2017-04-14-3

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 211794
DEA: 044G5104
EFIS: 0412000483
DIST-CO-RTE-PM04-SOL-80-31.4,32.6
Award Date01/20/2017
Closeout Date09/12/2019
Work DescriptionBRIDGE CONSTRUCTION
Location DescriptionSOLANO COUNTY IN AND NEAR VACAVILLE AT MERIDIAN ROAD OVERCROSSING AND AT MIDWAY ROAD OVERCROSSING
QA Service Level1 (Verified on 01/03/2017)

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

Sample Information

Sample Taken Date04/14/2017 Sample Unique Key3
Date that the sample was received by the laboratory/organization performing the testing04/18/2017 Sample typeQuality Assurance
A brief description of the sampleFlash Welded Rebar Hoops The quantity of what the sample constitutes4
From where was the sample collectedManufacturer First name of sampler or witnessed byGary
Last name of sampler or witnessed byMaComb Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameCMC Rebar
Transportation Laboratory (TL) NumberC970931 Inspector Lot Number from the Transportation Laboratory (TL) FormL1003717
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)4065065
Hoop Manufacturer Lot Number(s)1 Material Standard CodeASTM A706
Material Grade60 Rebar Size7
Diameter of Hoop4'-7" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCMC Rebar
Welding CompanyCMC Rebar (Etiwanda) Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2017-04-14-3-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory04/18/201704/18/2017
Yes
04/25/2017Bar Broke; OK NeckingPublic - Test Data Visible
2017-04-14-3-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory04/18/201704/18/2017
Yes
04/25/2017Bar Broke; OK NeckingPublic - Test Data Visible
2017-04-14-3-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory04/18/201704/18/2017
Yes
04/25/2017Bar Broke; OK NeckingPublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2017-04-14-3-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-04-14-3-2 CTM 670-December 2013 (Verified)