Sample Record

DIME Sample ID 2024-11-07-52

Project Information

Project IdentifiersProject ID: 995067
DEA: 11430394
EFIS: 1118000115
DIST-CO-RTE-PM11-SD-805-23.9/25.1
Award Date11/03/2023
Closeout DateNot set
Work DescriptionWIDEN FREEWAY, STRUCTURES, CONSTRUCT SIGNS, LANDSCAPE AND ELECTRICAL.
Location DescriptionSAN DIEGO COUNTY IN SAN DIEGO FROM 0.2 MILE NORTH OF ROUTE 805/52 SEPARATION TO 0.3 MILE SOUTH OF NOBEL DRIVE OVERCROSSING
QA Service Level1 (Verified on 12/19/2023)

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

Sample Information

Sample Taken Date11/07/2024 Sample Unique Key52
Date that the sample was received by the laboratory/organization performing the testing11/14/2024 Sample typeQuality Assurance
A brief description of the sample#8 Lenton Couplers The quantity of what the sample constitutes4
From where was the sample collectedJob Site First name of sampler or witnessed byDoug
Last name of sampler or witnessed byna Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameCMC Erico
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCMC
Coupler ManufacturerErico Intermediate Assembler or Fabricator
Rebar Size#8 Coupler ModelLenton A2
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)M0099 Rebar Heat Number(s)9004392
Rebar Size 2 Coupler Unique IDST-17-01

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2024-11-07-52-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Necking)Alexis Vargas-Bastida, CT HQ - Sacramento Structural Materials Testing Laboratory12/02/202412/05/2024
Yes
12/06/2024Atlas Technical ConsultantsPublic - Test Data Visible
2024-11-07-52-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Slip)Alexis Vargas-Bastida, CT HQ - Sacramento Structural Materials Testing Laboratory12/06/202412/05/2024
Yes
12/06/2024Atlas Technical ConsultantsPublic - Test Data Visible
2024-11-07-52-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Alexis Vargas-Bastida, CT HQ - Sacramento Structural Materials Testing Laboratory12/02/202412/05/2024
Yes
12/06/2024Atlas Technical ConsultantsPublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2024-11-07-52-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2024-11-07-52-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2024-11-07-52-3 CTM 670-December 2013 (Verified)