Sample Record

Owner Lab

  • CT D01 - District 1 Materials Laboratory

DIME Sample ID 2024-10-22-23

Project Information

Project IdentifiersProject ID: 994116
DEA: 010J4104
EFIS: 0119000025
DIST-CO-RTE-PM01-HUM-299-30.7/33.4
Award Date11/23/2022
Closeout DateNot set
Work DescriptionProject Name: HUM-299 Curve Improvement
Location DescriptionHUMBOLDT COUNTY NEAR WILLOW CREEK FROM 0.1 MILE EAST OF CEDAR CREEK ROAD TO 0.1 MILE EAST OF EAST FORK WILLOW CREEK BRIDGE
QA Service Level1 (Verified on 07/29/2022)

Sample Information

Sample Taken Date10/22/2024 Sample Unique Key23
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/23/2024
Sample typeQuality Assurance A brief description of the sampleTYPE II/V CEMENT
The quantity of what the sample constitutes267 CY From where was the sample collectedJob Site
First name of sampler or witnessed bySami Last name of sampler or witnessed byDaouk
Title of samplerASR Telephone number of sampler7074960700
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameEureka Ready Mix Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier12-04E0052
Structure nameRW A Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberE675WRF
The truck number from where the sample was collected79 The batch plant ticket number from where the sample was collected39684
Concrete batch plantArcata Eureka Ready Mix The fabricator/manufacturer designation for the sampleBatch
A detailed description of where the material sample was collectedCHUTE FROM TRUCK Where the material sample would have been placed if not sampledRW A Barrier Slab
From Lot No. Bag Lot No.

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2024-10-22-23-1CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete CylindersTom Brown, CT D01 - District 1 Materials Laboratory11/19/202411/19/2024
Yes
11/19/202428 Day Break 11/19/24 no 42 day break if 28 day break is over 3600 psiPublic - Test Data Visible
2024-10-22-23-3ASTM C1064-17: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement ConcreteSami Daouk, CT D01 - District 1 Materials Laboratory10/22/202410/23/2024
Yes
10/23/2024Ambient T = 47°Public - Test Data Visible
2024-10-22-23-4ASTM C143-20: Standard Test Method for Slump of Hydraulic-Cement ConcreteSami Daouk, CT D01 - District 1 Materials Laboratory10/22/202410/23/2024
Yes
10/23/2024Public - Test Data Visible
2024-10-22-23-6THIS TEST HAS BEEN SUPERSEDED.
CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Tom Brown, CT D01 - District 1 Materials Laboratory10/29/202410/29/2024
Yes
10/29/2024THIS TEST HAS BEEN SUPERSEDED.
7 Day Break 10/29/24
Public - Test Data Visible
2024-10-22-23-7CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete CylindersTom Brown, CT D01 - District 1 Materials Laboratory10/29/202410/29/2024
Yes
11/20/20247 Day Break 10/29/24Public - Test Data Visible
2024-10-22-23-8CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete CylindersTom Brown, CT D01 - District 1 Materials Laboratory12/03/202412/03/2024
Yes
12/03/2024Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2024-10-22-23-1 CTM 521-June 2020 (Verified)
DIME Test ID: 2024-10-22-23-3 ASTM C1064-17 (Verified)
DIME Test ID: 2024-10-22-23-4 ASTM C143-20 (Verified)
DIME Test ID: 2024-10-22-23-6 CTM 521-June 2020 (Verified)
DIME Test ID: 2024-10-22-23-7 CTM 521-June 2020 (Verified)
DIME Test ID: 2024-10-22-23-8 CTM 521-June 2020 (Verified)