Sample Record
Owner Lab
- SHN Engineers & Geologists, Incorporated
DIME Sample ID 2023-09-29-52
Project Information
| Project Identifiers | Project ID: 994116 DEA: 010J4104 EFIS: 0119000025 |
|---|---|
| DIST-CO-RTE-PM | 01-HUM-299-30.7/33.4 |
| Award Date | 11/23/2022 |
| Closeout Date | Not set |
| Work Description | Project Name: HUM-299 Curve Improvement |
| Location Description | HUMBOLDT COUNTY NEAR WILLOW CREEK FROM 0.1 MILE EAST OF CEDAR CREEK ROAD TO 0.1 MILE EAST OF EAST FORK WILLOW CREEK BRIDGE |
| QA Service Level | 1 (Verified on 07/29/2022) |
Sample Information
| Sample Taken Date | 09/29/2023 | Sample Unique Key | 52 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/30/2023 |
| Sample type | Quality Control | A brief description of the sample | 4x8 cylinders |
| The quantity of what the sample constitutes | 60 cy | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Dave | Last name of sampler or witnessed by | Gonzales |
| Title of sampler | special inspector | Telephone number of sampler | 707-599-5169 |
| Laboratory sample identification | C8937 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Eureka Ready mix | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Hwy 299 Soldier Pile Wall | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | E675WRF |
|---|---|---|---|
| The truck number from where the sample was collected | 282 | The batch plant ticket number from where the sample was collected | 32477 |
| Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
| A detailed description of where the material sample was collected | Concrete sample from wheelbarrow | Where the material sample would have been placed if not sampled | |
| From Lot No. | Bag Lot No. |
Submitted Tests
| DIME Test ID | Test Method | Tester Name, Testing Lab | Date Tested | Date Added | Verified? | Release Date | Test Comments | Privacy Level | Actions |
|---|---|---|---|---|---|---|---|---|---|
| 2023-09-29-52-11 | ASTM C1064-17: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete | Dave Gonzales, SHN Engineers & Geologists, Incorporated | 09/29/2023 | 11/15/2023 | No | See #2023-29-09-34 |
Go to page:
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2023-09-29-52-1 ASTM C1064-17 (Verified)
DIME Test ID: 2023-09-29-52-2 ASTM C231-17a (Verified)
DIME Test ID: 2023-09-29-52-3 ASTM C143-20 (Verified)
DIME Test ID: 2023-09-29-52-4 CTM 521-June 2020 (Verified)
DIME Test ID: 2023-09-29-52-5 CTM 521-June 2020 (Verified)
DIME Test ID: 2023-09-29-52-6 CTM 521-June 2020 (Verified)
DIME Test ID: 2023-09-29-52-7 CTM 521-June 2020 (Verified)
DIME Test ID: 2023-09-29-52-8 CTM 521-June 2020 (Verified)
DIME Test ID: 2023-09-29-52-9 CTM 521-June 2020 (Verified)
DIME Test ID: 2023-09-29-52-10 ASTM C138-17a (Verified)
DIME Test ID: 2023-09-29-52-11 ASTM C1064-17