Sample Record
DIME Sample ID 2021-12-20-6
Sample is locked from editing. info
Project Information
| Project Identifiers | Project ID: 211848 DEA: 112T2174 EFIS: 1116000131 |
|---|---|
| DIST-CO-RTE-PM | 11-SD-5-R37.4 - R46.5 |
| Award Date | 12/22/2016 |
| Closeout Date | 05/01/2026 |
| Work Description | (Alternative Delivery) CMGC, San Elijo Highway Bridge Replacement. Replace the San Elijo lagoon highway bridge, construct HOV lanes, construct bike and pedestrian trails and bridge, build multi-use facility at Manchester Ave. |
| Location Description | IN SAN DIEGO COUNTY IN SOLANA BEACH AND ENCINITAS FROM 0.1 MILE NORTH OF LOMAS SANTA FE DRIVE OVERCROSSING TO 0.2 MILE SOUTH OF BIRMINGHAM DRIVE OVERCROSSING |
| QA Service Level | 1 (Verified on 01/31/2017) |
Owner Lab
- CT D11 - District 11 Materials Laboratory
Sample Information
| Sample Taken Date | 12/20/2021 | Sample Unique Key | 6 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 12/20/2021 | Sample type | Quality Assurance |
| A brief description of the sample | 3/4" HMA PSU | The quantity of what the sample constitutes | 3 bags, 12 boxes, 3 cans |
| From where was the sample collected | Supplier | First name of sampler or witnessed by | David |
| Last name of sampler or witnessed by | Walker | Title of sampler | NOT PROVIDED |
| Telephone number of sampler | 8582480978 | Laboratory sample identification | 1307-PSU |
| Linked DIME Sample ID | 2021-12-20-5 | The fabricator/manufacturer/facility name | CCA Lakeside |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | Hanson Vigilante Rd. |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | HMA Plant | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/4 inch | |
| The concrete mix design number | 23417163 | Lot number | |
| Sublot number | Aggregate Mix Number | Not set |
Submitted Tests
Go to page:
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2021-12-20-6-11 CTM 204-June 2010 (Verified)
DIME Test ID: 2021-12-20-6-12 AASHTO T27-14 (Verified)
DIME Test ID: 2021-12-20-6-5 AASHTO T304-11 (Verified)
DIME Test ID: 2021-12-20-6-7 AASHTO T84-14 (Verified)
DIME Test ID: 2021-12-20-6-10 ASTM D4791-10 (Verified)
DIME Test ID: 2021-12-20-6-6 AASHTO T335-09r13 (Verified)
DIME Test ID: 2021-12-20-6-8 AASHTO T85-13 (Verified)
DIME Test ID: 2021-12-20-6-9 AASHTO T96-02r10 (Verified)
DIME Test ID: 2021-12-20-6-2 AASHTO T176-08 (Verified)
DIME Test ID: 2021-12-20-6-4 AASHTO T30-19 (Verified)
DIME Test ID: 2021-12-20-6-1 AASHTO T11-5 (Verified)