Sample Record

DIME Sample ID 2021-08-19-2

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 214175
DEA: 030H4804
EFIS: 0315000198
DIST-CO-RTE-PM03-SAC-99-0.1/1.6,11.8/21.6
Award Date08/20/2019
Closeout Date08/11/2023
Work DescriptionCOLD PLANE AC PAVEMENT AND RHMA OVERLAY.
Location DescriptionSACRAMENTO COUNTY IN AND NEAR GALT FROM DRY CREEK BRIDGE TO SIMMERHORN ROAD AND IN ELK GROVE AND SACRAMENTO FROM 0.9 MILE SOUTH OF ELK GROVE BOULEVARD TO MARTIN LUTHER KING JR BOULEVARD
QA Service Level1 (Verified on 05/29/2019)

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

Sample Information

Sample Taken Date08/19/2021 Sample Unique Key2
Date that the sample was received by the laboratory/organization performing the testing08/24/2021 Sample typeQuality Assurance
A brief description of the sample3/4" x 4-1/2" A325 Hex Bolts The quantity of what the sample constitutes900
From where was the sample collectedFabricator First name of sampler or witnessed byDavid
Last name of sampler or witnessed byLund Title of samplerCT METS QA INSPECTOR
Telephone number of sampler(385) 447-0624 Laboratory sample identificationna
Linked DIME Sample IDna The fabricator/manufacturer/facility nameUniversal Industrial Sales, Inc
Transportation Laboratory (TL) Numberna Inspector Lot Number from the Transportation Laboratory (TL) FormB390-128-21
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)NA
Heat Number(s)10707820 Nut Mfg. Lot Number(s)NA
Washer Mfg. Lot Number(s)NA Bolt SpecificationA325
Bolt Length(s)4-1/2" Nut SpecificationNA
Washer SpecificationNA FinishHot Dip Galvanize
Diameter/Size3/4" Bolt Mfg. Lot NumberBG2046
Rocap Test Requirement(s)NA Lubricant Requirements(s)NA
Washer Inner Diameter(s) Bolt Mill SupplierNot set
Nut Mill SupplierNot set Washer Mill SupplierNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2021-08-19-2-11ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)Steven Paine, CT HQ - Sacramento Structural Materials Testing Laboratory08/31/2021
Yes
09/01/2021Public - Test Data Visible
2021-08-19-2-12ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)Steven Paine, CT HQ - Sacramento Structural Materials Testing Laboratory08/31/2021
Yes
09/01/2021Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2021-08-19-2-1 ASTM F606-14a (Verified)
DIME Test ID: 2021-08-19-2-2 ASTM F606-14a (Verified)
DIME Test ID: 2021-08-19-2-3 ASME B1.2-83r01 (Verified)
DIME Test ID: 2021-08-19-2-4 ASME B1.2-83r01 (Verified)
DIME Test ID: 2021-08-19-2-5 ASME B1.2-83r01 (Verified)
DIME Test ID: 2021-08-19-2-6 ASME B1.2-83r01 (Verified)
DIME Test ID: 2021-08-19-2-7 ASME B1.2-83r01 (Verified)
DIME Test ID: 2021-08-19-2-8 ASTM B499-14 (Verified)
DIME Test ID: 2021-08-19-2-9 ASTM B499-14 (Verified)
DIME Test ID: 2021-08-19-2-10 ASTM B499-14 (Verified)
DIME Test ID: 2021-08-19-2-11 ASTM B499-14 (Verified)