Sample Record
Owner Lab
- CT HQ - Sacramento Structural Materials Testing Laboratory
DIME Sample ID 2020-07-06-7
Sample is locked from editing. info
Project Information
| Project Identifiers | Project ID: 212112 DEA: 080C2514 EFIS: 0816000076 COOP: 081645 |
|---|---|
| DIST-CO-RTE-PM | 08-SBD-10-0.0/13.2 |
| Award Date | 06/06/2018 |
| Closeout Date | Not set |
| Work Description | Design-Build of I-10 Corridor Contract 1 - Adding 2 new Express Lanes |
| Location Description | LA/SBD County Line to PM 13.2 near I-15 |
| QA Service Level | 1 (Verified on 10/16/2019) |
Sample Information
| Sample Taken Date | 07/06/2020 | Sample Unique Key | 7 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 07/13/2020 | Sample type | Quality Assurance |
| A brief description of the sample | #8 Threadbar | The quantity of what the sample constitutes | 5765 ea. |
| From where was the sample collected | Source | First name of sampler or witnessed by | Clifford |
| Last name of sampler or witnessed by | William | Title of sampler | QA Inspector |
| Telephone number of sampler | 17142674733 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Nucor | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | L78-071-20 | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Threaded Bar | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Threaded Bar Specification | ASTM A615 | Threaded Bar Grade | 80 |
| Threaded Bar Type | Deformed | Rebar Size | #8 |
| Nut Specification for Threaded Bar | ASTM A108 | System Manufacturer | Nucor |
| Epoxy Coating Color | NA | Threaded Bar Application | Soil Nail |
| Coating Standards | Uncoated | Bar Heat Number(s) | 3700008043, 3700009512, 3700009513, BR1910025 |
| Nut Heat Number(s) | 100101595N-01, 100101595N, 100792995-02, 8390 | Bar Lot Number | |
| Nut Lot Number | 5297, 5319, 5180, 5284 | Coupler Heat Number(s) | N/A |
| Coupler Grade | N/A |
Submitted Tests
Go to page:
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2020-07-06-7-1 ASTM A615-15 (Verified)
DIME Test ID: 2020-07-06-7-2 ASTM A615-15 (Verified)
DIME Test ID: 2020-07-06-7-3 ASTM A615-15 (Verified)
DIME Test ID: 2020-07-06-7-4 ASTM A615-15 (Verified)
DIME Test ID: 2020-07-06-7-5 ASTM A615-15 (Verified)
DIME Test ID: 2020-07-06-7-6 ASTM A615-15 (Verified)
DIME Test ID: 2020-07-06-7-7 ASTM A615-15 (Verified)
DIME Test ID: 2020-07-06-7-8 ASTM A615-15 (Verified)
DIME Test ID: 2020-07-06-7-9 ASTM A615-15 (Verified)
DIME Test ID: 2020-07-06-7-10 ASTM A615-15 (Verified)
DIME Test ID: 2020-07-06-7-11 ASTM A615-15 (Verified)
DIME Test ID: 2020-07-06-7-12 ASTM A615-15 (Verified)
DIME Test ID: 2020-07-06-7-13 ASTM A615-15 (Verified)
DIME Test ID: 2020-07-06-7-14 ASTM A615-15 (Verified)