Sample Record
Owner Lab
- CT HQ - Sacramento Aggregate Testing Laboratory
DIME Sample ID 2019-04-17-54
Sample is locked from editing. info
Project Information
| Project Identifiers | Project ID: 66667 DEA: JMFPP EFIS: 0019000043 |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for submitting Sample information for JMF Prequalification Program. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 04/17/2019 | Sample Unique Key | 54 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 07/18/2019 | Sample type | Verification |
| A brief description of the sample | 3/4" HMA - A | The quantity of what the sample constitutes | 1 |
| From where was the sample collected | Source | First name of sampler or witnessed by | Iggy |
| Last name of sampler or witnessed by | Herrera | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | 19-JMF-0118 replace with 19-JMF-0129 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Granite Construction Company Vernalis | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-39-0002::VERNALIS |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
| The plant number | Unknown | A detailed description of where the material sample was collected | Stockpile @ Plant |
| Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | 3/4 inch |
| The concrete mix design number | Unknown | Lot number | Unknown |
| Sublot number | Unknown | Aggregate Mix Number | Not set |
JMF Information
| Verification ID | JMF3513-2019-76 | Date Created | 07/30/2019 |
|---|---|---|---|
| JMF Submittal ID | JMF3511-208-2019-111 | JMF Status | Submittal Accepted for Verification |
| Producer Mix ID | 2708 | Authorized Date | N/A |
Submitted Tests
Go to page:
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2019-04-17-54-8 CTM 204-June 2010 (Verified)
DIME Test ID: 2019-04-17-54-9 AASHTO T11-5 (Verified)
DIME Test ID: 2019-04-17-54-10 AASHTO T27-14 (Verified)
DIME Test ID: 2019-04-17-54-1 AASHTO T335-09r13 (Verified)
DIME Test ID: 2019-04-17-54-2 AASHTO T335-09r13 (Verified)
DIME Test ID: 2019-04-17-54-6 AASHTO T304-11 (Verified)
DIME Test ID: 2019-04-17-54-4 AASHTO T96-02r10 (Verified)
DIME Test ID: 2019-04-17-54-5 AASHTO T176-08 (Verified)
DIME Test ID: 2019-04-17-54-7 ASTM D4791-10 (Verified)
DIME Test ID: 2019-04-17-54-12 AASHTO T85-13 (Verified)
DIME Test ID: 2019-04-17-54-13 AASHTO T85-13 (Verified)
DIME Test ID: 2019-04-17-54-14 AASHTO T85-13 (Verified)
DIME Test ID: 2019-04-17-54-11 AASHTO T84-14 (Verified)
DIME Test ID: 2019-04-17-54-3 AASHTO T335-09r13 (Verified)