Sample Record
Owner Lab
- CT HQ - QASI Sacramento Field Office
DIME Sample ID 2019-08-08-21
Sample is locked from editing. info
Project Information
| Project Identifiers | Project ID: 213261 DEA: 071XH004 EFIS: 0718000239 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-47-.86, 0.86, 0.86 |
| Award Date | 03/20/2018 |
| Closeout Date | 06/03/2020 |
| Work Description | Remove and replace the two (2) long finger joint assemblies at Bents 11 and 12 and repair the elevators in both towers |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 06/08/2018) |
Sample Information
| Sample Taken Date | 08/08/2019 | Sample Unique Key | 21 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/09/2019 |
| Sample type | Department Acceptance | A brief description of the sample | 7/8 - 9 x 7 A325 |
| The quantity of what the sample constitutes | 110 | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Jamie | Last name of sampler or witnessed by | Doe |
| Title of sampler | QA Inspector | Telephone number of sampler | 916-838-4505 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | CK Johnson | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | S50-018-19 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | 812525R |
|---|---|---|---|
| Heat Number(s) | 10550960, 21807850, DL18101099 | Nut Mfg. Lot Number(s) | 406805A |
| Washer Mfg. Lot Number(s) | D5899 | Bolt Specification | A325 |
| Bolt Length(s) | 7" | Nut Specification | A563 |
| Washer Specification | F436 | Finish | HDG |
| Diameter/Size | 7/8 - 9 | Bolt Mfg. Lot Number | 812525 |
| Rocap Test Requirement(s) | Yes | Lubricant Requirements(s) | Yes |
| Washer Inner Diameter(s) |
Submitted Tests
Go to page:
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2019-08-08-21-1 ASTM F606-14a (Verified)
DIME Test ID: 2019-08-08-21-2 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-08-08-21-3 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-08-08-21-4 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-08-08-21-5 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-08-08-21-6 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-08-08-21-7 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-08-08-21-8 ASTM B499-14 (Verified)
DIME Test ID: 2019-08-08-21-9 ASTM B499-14 (Verified)
DIME Test ID: 2019-08-08-21-10 ASTM B499-14 (Verified)
DIME Test ID: 2019-08-08-21-11 ASTM B499-14 (Verified)
DIME Test ID: 2019-08-08-21-12 ASTM B499-14 (Verified)
DIME Test ID: 2019-08-08-21-13 ASTM B499-14 (Verified)
DIME Test ID: 2019-08-08-21-14 ASTM B499-14 (Verified)
DIME Test ID: 2019-08-08-21-15 ASTM B499-14 (Verified)
DIME Test ID: 2019-08-08-21-16 ASTM B499-14 (Verified)
DIME Test ID: 2019-08-08-21-17 ASTM E18-15 (Verified)
DIME Test ID: 2019-08-08-21-18 ASTM E18-15 (Verified)