Summary for Test 2015-04-17-7-1
Test performed: ASTM C39-10Project Information
Project Identifiers | Project ID: 209864 DEA: 043G1204 EFIS: 0400021276 |
---|---|
DIST-CO-RTE-PM | 04-SON-128-1.8 |
Award Date | 12/12/2014 |
Closeout Date | 06/29/2016 |
Work Description | CONSTRUCT SOLDIER PILE WALL AND PLACE CULVERT. |
Location Description | SONOMA COUNTY NEAR CLOVERDALE ABOUT 3.1 MILES WEST OF NORTH CLOVERDALE BOULEVARD |
QA Service Level | 1 (Verified on 01/22/2015) |
Sample Information
Sample Taken Date | 04/17/2015 | Sample Unique Key | 7 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/24/2015 |
Sample type | Verification | A brief description of the sample | concrete cylinders |
The quantity of what the sample constitutes | 2 concrete cylinders | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Steve | Last name of sampler or witnessed by | Acton |
Title of sampler | SR | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | field | Transportation Laboratory (TL) Number | 059146 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Unknown |
Structure name | Unknown |
Material Information
Material Type | Concrete | The concrete mix design number | 9796 |
---|---|---|---|
The truck number from where the sample was collected | Unknown | The batch plant ticket number from where the sample was collected | na |
Concrete batch plant | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
A detailed description of where the material sample was collected | field | Where the material sample would have been placed if not sampled | Not set |
From Lot No. | Not set | Bag Lot No. | Not set |
Test Details
DIME Sample ID: 2015-04-17-7
DIME Test ID: 2015-04-17-7-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2015-04-27
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Mullins
Date of test: 04/27/2015
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.01 in
Maximum load on cylinder 1: 94842 lb
Maximum load on cylinder 2: 94078 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: no data
Age of specimen: 10 days
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.37 in^2
Compressive strength of cylinder 1: 3354.9 psi
Compressive strength of cylinder 2: 3316.1 psi
Compressive strength (to nearest 10 psi): 3340 psi
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point FileTest graph for Cylinder Code 1 of 2
Source: Partner Data Point File
Test graph for Cylinder Code 2 of 2
Test was verified on 4/27/2015 ✔