Summary for Test 2015-04-17-5-1
Test performed: CTM 202-November 2011Project Information
Project Identifiers | Project ID: 600 DEA: 02378904 EFIS: 0200000288 |
---|---|
DIST-CO-RTE-PM | 02-SHA-5-R63.2/R65.8 |
Award Date | 09/25/2009 |
Closeout Date | 12/01/2021 |
Work Description | BRIDGE REPLACEMENT |
Location Description | IN SHASTA COUNTYNEAR LAKEHEAD FROM 0.3 KM NORTH OF ANTLER SUMMIT OVERCROSSING TO 0.5 KM NORTH OFANTLER UNDERPASS |
QA Service Level | 1 (Verified on 03/19/2012) |
Sample Information
Sample Taken Date | 04/17/2015 | Sample Unique Key | 5 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/17/2015 |
Sample type | Quality Assurance | A brief description of the sample | Fine aggregate |
The quantity of what the sample constitutes | 1 bag | From where was the sample collected | Source |
First name of sampler or witnessed by | D | Last name of sampler or witnessed by | Hanson |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | 15FPCC-0223 | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Tutor Saliba | Transportation Laboratory (TL) Number | C853580C |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | NA |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
The plant number | Unknown | A detailed description of where the material sample was collected | Batch Plant |
Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | |
The concrete mix design number | Lot number | Not set | |
Sublot number | Not set | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2015-04-17-5
DIME Test ID: 2015-04-17-5-1
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2015-04-27
Test Results
What size aggregate is being tested?: Fine Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Calculated
Tester's full name: Thomas Stinnett
Date of test: 04/17/2015
Cumulative percent passing the 3/8 in. sieve: 100 %
Cumulative percent passing the #4 sieve: 99 %
Cumulative percent passing the #8 sieve: 77 %
Cumulative percent passing the #16 sieve: 52 %
Cumulative percent passing the #30 sieve: 29 %
Cumulative percent passing the #50 sieve: 10 %
Cumulative percent passing the #100 sieve: 2 %
Cumulative percent passing the #200 sieve: 1 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/27/2015 ✔