Summary for Test 2015-04-14-7-1
Test performed: CTM 521-November 2014
Warning: The test results shown on this page have been superseded and are invalid.
This information is for reference only.
Project Information
Project Identifiers | Project ID: 7427 DEA: 07215934 EFIS: 0700001833 |
---|---|
DIST-CO-RTE-PM | 07-LA-5-2.4/4.0 |
Award Date | 08/14/2012 |
Closeout Date | 02/20/2020 |
Work Description | Widen and Realign Freeway and Construct Ped OC, OC and UC Structures. |
Location Description | LOS ANGELES COUNTY IN SANTA FE SPRINGS AND NORWALK FROM 0.1 MILE NORTH OF CARMENITA ROAD OVERCROSSING TO 0.1 MILE NORTH OF SILVERBOW AVENUE PEDESTRIAN OVERCROSSING |
QA Service Level | 1 (Verified on 11/26/2012) |
Sample Information
Sample Taken Date | 04/14/2015 | Sample Unique Key | 7 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/20/2015 |
Sample type | Quality Control | A brief description of the sample | Concrete Cylinders |
The quantity of what the sample constitutes | 4 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Roy | Last name of sampler or witnessed by | Auer |
Title of sampler | ASR | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | site | Transportation Laboratory (TL) Number | 199550 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Unknown |
Structure name | Unknown |
Material Information
Material Type | Concrete | The concrete mix design number | s72036 |
---|---|---|---|
The truck number from where the sample was collected | load 3 | The batch plant ticket number from where the sample was collected | 161595 |
Concrete batch plant | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
A detailed description of where the material sample was collected | sta 19100 to 194 13 at RC1 | Where the material sample would have been placed if not sampled | Not set |
From Lot No. | Not set | Bag Lot No. | Not set |
Test Details
DIME Sample ID: 2015-04-14-7
DIME Test ID: 2015-04-14-7-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 521-November 2014: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2015-04-20
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 04/20/2015
Average diameter of cylinder 1: 6.01 in
Average diameter of cylinder 2: 6.00 in
Maximum load on cylinder 1: 86660 lb
Maximum load on cylinder 2: 89260 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Age of specimen: 6 days
Cross sectional area of cylinder 1: 28.37 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength of cylinder 1: 3,054.6 psi
Compressive strength of cylinder 2: 3,157.4 psi
Compressive strength (to nearest 10 psi): 3110 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/20/2015 ✔
Warning: The test results shown on this page have been superseded and are invalid.