Summary for Test 2020-10-13-31-1
Test performed: CTM 643-April 2020Project Information
Project Identifiers | Project ID: 215304 DEA: 010E0814 EFIS: 0118000172 |
---|---|
DIST-CO-RTE-PM | 01-LAK-20,29,175-Var |
Award Date | 09/20/2021 |
Closeout Date | Not set |
Work Description | Replace & widen bridges |
Location Description | LAKE COUNTY AT VARIOUS LOCATIONS |
QA Service Level | 1 (Verified on 11/04/2020) |
Sample Information
Sample Taken Date | 10/13/2020 | Sample Unique Key | 31 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/09/2020 |
Sample type | Per Request | A brief description of the sample | Native Soil |
The quantity of what the sample constitutes | 111.08g | From where was the sample collected | Job Site |
First name of sampler or witnessed by | S | Last name of sampler or witnessed by | Awad |
Title of sampler | Transportation Engineer | Telephone number of sampler | 925-864-1069 |
Laboratory sample identification | CR20200483 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Caltrans | Transportation Laboratory (TL) Number | C002411 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | 01-LAK--175-PM19.48 | |
Structure name | Kelsey Creek Bridge |
Material Information
Material Type | Soil | The fabricator's/manufacturer's product name for the sample | Soil Foundation RC-20-001 |
---|---|---|---|
The fabricator/manufacturer designation for the sample | Native Soil | A detailed description of where the material sample was collected | 0-5 feet depth |
Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2020-10-13-31
DIME Test ID: 2020-10-13-31-1
Testing Lab: WSP Environment & Infrastructure, Inc.
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Test Release Date: 2020-11-12
Test Results
The test method used?: Laboratory Resistivity Test for Soil (pH and Resistivity)
Input Type: Calculated
Tester's full name: Michael Gibson
Date of test: 11/10/2020
Minimum soil resistance of the lab measurement: 3750 Ohms
Soil sample temperature: 19.9 C
Soil box constant: 1
pH of soil: 7.22
Minimum soil resistance corrected to 15.5: 4163 Ohm-cm
Minimum soil resistivity at 15.5: 4163 Ohm-cm
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 11/12/2020 ✔