Summary for Test 2020-09-24-14-8

Test performed: AASHTO T240-17

Project Information

Project IdentifiersProject ID: 213469
DEA: 024C40V4
EFIS: 0218000125
DIST-CO-RTE-PM02-SHA-5-R3.8/R11.7
Award Date11/06/2018
Closeout Date08/16/2023
Work DescriptionWIDEN TO 6 LANES, BRIDGE REPLACEMENT AND WIDENING AND ROADWAY REHAB
Location DescriptionSHASTA COUNTY IN AND NEAR ANDERSON FROM ROUTE 5/273 SEPARATION TO 0.4 MILE SOUTH OF CHURN CREEK ROAD OVERCROSSING
QA Service Level1 (Verified on 12/31/2018)

Sample Information

Sample Taken Date09/24/2020 Sample Unique Key14
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/02/2020
Sample typeAcceptance A brief description of the sampleAsphalt Binder Sample #1 Test, #2 (853468) No test
The quantity of what the sample constitutes1 Can From where was the sample collectedDistributor
First name of sampler or witnessed byC Last name of sampler or witnessed byBryant
Title of samplerTET Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameValero - Benicia Transportation Laboratory (TL) Number037254
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 58-22
ModifiedNo Lot number
Sublot number Tank numberNot set
Time of sampleNot set HMA SupplierNot set
Certified Asphalt SupplierNot set MultigradeNot set
Multigrade TypeNot set Asphalt Binder Mix NumberNot set

Test Details

DIME Sample ID: 2020-09-24-14
DIME Test ID: 2020-09-24-14-8
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Test Release Date: 2020-10-21

Test Results


Is mass change based on one or two containers?: One
Input Type: Measured
Tester's full name: Ruben Macias
Date of test: 10/06/2020
Any material loss from containers during heating process/testing?: No
Mass of empty container #1: 0.000 grams
Mass of container #1 before test (m1i): 214.520 grams
Mass of container #1 after test (m1f): 214.370 grams
Average mass change: -0.421 percent
General comments (publicly viewable) (Max 1000 characters): Per 2018 Standard Specifications

Test was verified on 10/21/2020