Summary for Test 2020-06-18-42-8
Test performed: AASHTO T312-14Project Information
Project Identifiers | Project ID: 214571 DEA: 020J1104 EFIS: 0219000062 |
---|---|
DIST-CO-RTE-PM | 02-PLU-70-33.1/42.1 |
Award Date | 02/07/2020 |
Closeout Date | 04/27/2021 |
Work Description | PLACE HMA & SHOULDER BACKING, & REMOVE & REPLACE PAVEMENT DELINEATION. |
Location Description | PLUMAS COUNTY AT AND NEAR KEDDIE FROM INDIAN CREEK BRIDGE TO 0.3 MILE WEST OF SPANISH CREEK BRIDGE NO. 09-0018 |
QA Service Level | 1 (Verified on 01/22/2020) |
Sample Information
Sample Taken Date | 06/18/2020 | Sample Unique Key | 42 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/18/2020 |
Sample type | Verification | A brief description of the sample | 3/4-inch Type A HMA (PG 64-16) 15.0 RAP, 1.0 Lime |
The quantity of what the sample constitutes | JMF Verification | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | PEI | Last name of sampler or witnessed by | Joe |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | D78486 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Sierra Cascade Aggregate and Asphalt Products | Transportation Laboratory (TL) Number | 734736 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | |
Sublot number | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2020-06-18-42
DIME Test ID: 2020-06-18-42-8
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T312-14: Preparing and Determining the Density of Asphalt Mixture Specimens by Means of the Superpave Gyratory Compactor (Method of Compaction)
Test Release Date: 2020-10-05
Test Results
HMA Type: Type A HMA
Is this test used for JMF verification:
Input Type: Measured
Tester's full name: Terry McCormick
Date of test: 06/19/2020
Start time of test (military time): 0826
Specimen identification: 2061901
Percent Binder Content: 5.9 %
Average diameter of the mold: 150 mm
Height of the extruded specimen (Hm): 115.1 mm
Mass of the specimen: 4665.8 g
Maximum Specific Gravity (Gmm): 2.444
Bulk Specific Gravity (Gmb): 2.382
Unit weight of water: 1 g/cm^3
Gyration Angle: 1.16 deg
Gyration Angle: 20.2 mrad
Method used to verify gyration angle: AASHTO T 344 at room temperature
Uncorrected relative density (Gmmu8): 84.2 %
Uncorrected relative density (Gmmu85): 92.6 %
Uncorrected relative density (Gmmu130): 93.9 %
Air Voids (AV8): 12.6 %
Air Voids (AV85): 3.9 %
Air Voids (AV130): 2.5 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/5/2020 ✔