Summary for Test 2020-09-09-5-3

Test performed: ASTM F606-14

Project Information

Project IdentifiersProject ID: 88888
DEA: SMTL-STOCK
EFIS: SMTL-STOCK
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date09/09/2020 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/14/2020
Sample typeQuality Assurance A brief description of the sampleASTM F1554 Gr 55 Anchor Bolt
The quantity of what the sample constitutes153 From where was the sample collectedSource
First name of sampler or witnessed byVikram Last name of sampler or witnessed bySingh
Title of samplerQA Inspector Telephone number of sampler5106609027
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameAM Nut and Bolt Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL109-003-20 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)3093323 Nut Mfg. Lot Number(s)31489-6215014605
Washer Mfg. Lot Number(s)309577 Bolt SpecificationASTM F1554-15 Gr. 55
Bolt Length(s)12” Nut SpecificationASTM A194 Gr. 2H
Washer SpecificationASTM F436 FinishHDG
Diameter/Size5/8” Bolt Mfg. Lot Number50621-PPO
Rocap Test Requirement(s) Lubricant Requirements(s)

Test Details

DIME Sample ID: 2020-09-09-5
DIME Test ID: 2020-09-09-5-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Test Release Date: 2020-09-17

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 09/15/2020
UTM: 400kip
Temperature: 72
NumSampleSizeArea (in^2)Peak Load (lbf)Peak Load (kN)Tensile Strength (psi)Stress at Offset (psi)Load at Offset (lbf)Comments
11UNC 5/8 0.2262020589893846304114247F1554 Rod

General comments (publicly viewable) (Max 1000 characters): F1554 Rod
Test Graph
Source: Bluehill Data Point File

Test was verified on 9/17/2020