Summary for Test 2020-08-25-24-1

Test performed: AASHTO T59-16

Project Information

Project IdentifiersProject ID: 214731
DEA: 051M0004
EFIS: 0519000047
DIST-CO-RTE-PM05-SLO-101-16.5/R21.5
Award Date04/22/2020
Closeout Date08/23/2021
Work DescriptionCOLD PLANE AND RHMA-GAP GRADED OVERLAY ON EXISTING ROADWAY.
Location DescriptionSAN LUIS OBISPO COUNTY IN AND NEAR PISMO BEACH FROM 0.1 MILE SOUTH OF PRICE CANYON ROAD TO SAN LUIS CREEK BRIDGE
QA Service Level1 (Verified on 05/29/2020)

Sample Information

Sample Taken Date08/25/2020 Sample Unique Key24
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/02/2020
Sample typeDepartment Acceptance A brief description of the sample#1 Test emulsion CQS-1h
The quantity of what the sample constitutes1 gallon jug From where was the sample collectedJob Site
First name of sampler or witnessed bysiraj Last name of sampler or witnessed bysarieddine
Title of samplerARE Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameVSS Emultech Transportation Laboratory (TL) Number200831A
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphaltic Emulsion Emulsion GradeCQS-1h
Lot NumberNot set Sub LotNot set

Test Details

DIME Sample ID: 2020-08-25-24
DIME Test ID: 2020-08-25-24-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T59-16: Standard Method of Test for Emulsified Asphalts (Residue and Oil Distillate (Sec. 6))
Test Release Date: 2020-09-11

Test Results


What parameters are being calculated?: Percentage of oil residue
Is this a polymer-modified emulsion: No
Input Type: Measured
Tester's full name: Eva Torres
Date of test: 09/10/2020
Mass of the distillation pot, accessories, and reside after the test: 2407.9 g
Mass of distillation pot and accessories before test: 2287.3 g
Correction Factor: 1.5
Mass of the distallation pot, accessories, and reside after the test w/ correction factor: 2409.4 g
Percentage of oil residue: 61.0 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/11/2020