Summary for Test 2020-08-18-30-5
Test performed: AASHTO T308-10
Warning: The test results shown on this page have been superseded and are invalid.
This information is for reference only.
Project Information
Project Identifiers | Project ID: 210673 DEA: 042640F4 EFIS: 0400020132 COOP: 042308A3 |
---|---|
DIST-CO-RTE-PM | 04-SON-- |
Award Date | 08/08/2019 |
Closeout Date | 02/16/2024 |
Work Description | Not set |
Location Description | Not set |
QA Service Level | 1 (Verified on 04/11/2022) |
Sample Information
Sample Taken Date | 08/18/2020 | Sample Unique Key | 30 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | Not set |
Sample type | Verification | A brief description of the sample | Hot mix asphalt in boxes |
The quantity of what the sample constitutes | 24 boxes | From where was the sample collected | Source |
First name of sampler or witnessed by | CT Anthony | Last name of sampler or witnessed by | Valdez |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Bodean Mark West Quarry | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 1/2 inch | Lot number | |
Sublot number | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2020-08-18-30
DIME Test ID: 2020-08-18-30-5
Testing Lab: CT D04 - Hayward DME / District Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2020-09-02
Test Results
What temperature unit is used?: Fahrenheit
Input Type: Measured
Tester's full name: Reza Dineli
Date of test: 08/28/2020
Test procedure used?: Method A
Mass of the specimen basket assembly: no data
Mass of the specimen and specimen basket assembly prior to ignition: no data
Mass of HMA Sample prior to ignition: 1555.8 g
Mass Loss: no data
Mass of aggregate remaining after ignition: 1460.4 g
Correction Factor (Percent by mass of HMA Specimen): 0.33 %
Moisture Content: 0.00 %
Temperature Compensation Factor: no data
Test Temperature: 1000.4 F
Corrected Asphalt Binder Content: 5.80 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/2/2020 ✔
Warning: The test results shown on this page have been superseded and are invalid.
This information is for reference only.