Summary for Test 2020-07-29-22-1
Test performed: ASTM C39-10Project Information
Project Identifiers | Project ID: 213764 DEA: 080F0304 EFIS: 0800020358 |
---|---|
DIST-CO-RTE-PM | 08-SBD-60-R0.7/R3.0 |
Award Date | 03/07/2019 |
Closeout Date | 07/27/2023 |
Work Description | REMOVE AND REPLACE THREE OVERCROSSING BRIDGES ON ROUTE 60 |
Location Description | IN SAN BERNARDINO COUNTY IN AND NEAR CHINO AT VARIOUS LOCATIONS FROM O.1 MILE WEST OF PIPELINE AVENUE OVERCROSSING TO 0.1 MILE EAST OF BENSON AVENUE OVERCROSSING |
QA Service Level | 1 (Verified on 05/01/2019) |
Sample Information
Sample Taken Date | 07/29/2020 | Sample Unique Key | 22 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/05/2020 |
Sample type | Quality Assurance | A brief description of the sample | 6x12 Concrete Cylinders |
The quantity of what the sample constitutes | 4 Concrete Cylinders | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Victor | Last name of sampler or witnessed by | Wami |
Title of sampler | ASR | Telephone number of sampler | |
Laboratory sample identification | 1003-29 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Robertsons | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name | Stage 1 CIDH Piles for Abutment 3 Footing |
Material Information
Material Type | Concrete | The concrete mix design number | RRM18086 |
---|---|---|---|
The truck number from where the sample was collected | 1963 | The batch plant ticket number from where the sample was collected | 5493683 |
Concrete batch plant | Robertsons Ready Mix | The fabricator/manufacturer designation for the sample | |
A detailed description of where the material sample was collected | Chute at 35 Cubic Yards Placed | Where the material sample would have been placed if not sampled | Stage 1 CIDH Piles for Abutment 3 Footing |
From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2020-07-29-22
DIME Test ID: 2020-07-29-22-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2020-09-02
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 08/26/2020
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.03 in
Average diameter of cylinder 2: 6.02 in
Maximum load on cylinder 1: 112710 lb
Maximum load on cylinder 2: 111470 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Age of specimen: 28 days
Cross sectional area of cylinder 1: 28.56 in^2
Cross sectional area of cylinder 2: 28.46 in^2
Compressive strength of cylinder 1: 3946.4 psi
Compressive strength of cylinder 2: 3916.7 psi
Compressive strength (to nearest 10 psi): 3930 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/2/2020 ✔