Summary for Test 2020-08-20-7-2

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 88888
DEA: SMTL-STOCK
EFIS: SMTL-STOCK
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date08/20/2020 Sample Unique Key7
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/20/2020
Sample typeQuality Assurance A brief description of the sampleA 325 bolt Assembly
The quantity of what the sample constitutes12/1932 Bolts, 12/1932 Nuts, 12/3864 Washers From where was the sample collectedFabricator
First name of sampler or witnessed byDong Last name of sampler or witnessed byShin
Title of samplerQA Inspector Telephone number of sampler205-999-5798
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameUIS Lindon UT Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormB 314-060-20 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)TT0130531
Heat Number(s)10288950 Nut Mfg. Lot Number(s)17-04-005
Washer Mfg. Lot Number(s)956-191079 Bolt SpecificationASTM A 325
Bolt Length(s)2" Nut SpecificationASTM A563
Washer SpecificationASTM F436 FinishMG
Diameter/Size1/2" Bolt Mfg. Lot NumberBM0088
Rocap Test Requirement(s)YES Lubricant Requirements(s)No

Test Details

DIME Sample ID: 2020-08-20-7
DIME Test ID: 2020-08-20-7-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2020-09-02

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 08/27/2020
UTM: 450kip
Temperature: 72 f
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
17B17-04-00523017Nut Prooffsaylor

General comments (publicly viewable) (Max 1000 characters): Nut Proof
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.

Test was verified on 9/2/2020