Summary for Test 2020-08-20-5-4
Test performed: ASTM F606-14aProject Information
Project Identifiers | Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 08/20/2020 | Sample Unique Key | 5 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/20/2020 |
Sample type | Quality Assurance | A brief description of the sample | A 325 bolt Assembly |
The quantity of what the sample constitutes | 12/286 Bolts, 12/300 Nuts, 12/600 Washers | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Dong | Last name of sampler or witnessed by | Shin |
Title of sampler | QA Inspector | Telephone number of sampler | 205-999-5798 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | UIS Lindon UT | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B 314-058-20 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | TT0130560 |
---|---|---|---|
Heat Number(s) | 100885850 | Nut Mfg. Lot Number(s) | 31634-6215105206 |
Washer Mfg. Lot Number(s) | 978-191084 | Bolt Specification | ASTM A 325 |
Bolt Length(s) | 4" | Nut Specification | ASTM A 563 |
Washer Specification | ASTM F 436 | Finish | MG |
Diameter/Size | 1-1/4" | Bolt Mfg. Lot Number | BM0549 |
Rocap Test Requirement(s) | YES | Lubricant Requirements(s) | No |
Test Details
DIME Sample ID: 2020-08-20-5
DIME Test ID: 2020-08-20-5-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2020-09-02
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 08/27/2020
UTM: 450kip
Temperature: 72 f
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
---|---|---|---|---|---|---|---|
1 | 5A | 31634-6215105206 | 150118 | Nut Proof | fsaylor |
General comments (publicly viewable) (Max 1000 characters): Nut Proof
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.
Test was verified on 9/2/2020 ✔