Summary for Test 2020-08-19-14-3

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 214701
DEA: 030F2844
EFIS: 0319000204
DIST-CO-RTE-PM03-SAC-99-7.1/9.4
Award Date05/14/2020
Closeout Date11/27/2023
Work DescriptionConstruct new PCC precast girder bridge over UPRR at McConnell OH between existing SB and NB alignments
Location DescriptionNot set
QA Service Level1 (Verified on 04/20/2020)

Sample Information

Sample Taken Date08/19/2020 Sample Unique Key14
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/24/2020
Sample typeQuality Assurance A brief description of the sample Couplers
The quantity of what the sample constitutes4 From where was the sample collectedManufacturer
First name of sampler or witnessed byChau Last name of sampler or witnessed byHa
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameHRC Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormC739852 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingAuthorization Testing
Service or UltimateUltimate Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCMC
Coupler ManufacturerHRC Intermediate Assembler or Fabricator
Rebar Size#11 Coupler ModelHRC 500/510
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)73116792, 73115502 Rebar Heat Number(s)3096955
Rebar Size 2 Coupler Unique IDNot set

Test Details

DIME Sample ID: 2020-08-19-14
DIME Test ID: 2020-08-19-14-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2020-08-25

Test Results


Number of Samples Tested: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 08/25/2020
UTM: 2000kip
Temperature: 72.00 f
Halo ID:
NumSampleNumber of CyclesSizeMfg. Lot Number(s)Slip (inch)Area (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
12No. 11/36mm101.5615238897684OK Neckingfsaylor

General comments (publicly viewable) (Max 1000 characters): OK Necking
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.

Test was verified on 8/25/2020