Summary for Test 2020-06-25-24-13
Test performed: AASHTO T315-16Project Information
Project Identifiers | Project ID: 214844 DEA: 060Y0704 EFIS: 0619000150 |
---|---|
DIST-CO-RTE-PM | 06-KER-155-49.5/R60.0 |
Award Date | 05/15/2020 |
Closeout Date | 10/22/2020 |
Work Description | PLACE HMA (TYPE A). |
Location Description | KERN COUNTY NEAR GLENNVILLE FROM 2.4 MILES EAST OF SANDY CREEK FIRE ROAD TO 0.1 MILE WEST OF ADAMS ROAD |
QA Service Level | 1 (Verified on 04/20/2020) |
Sample Information
Sample Taken Date | 06/25/2020 | Sample Unique Key | 24 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/06/2020 |
Sample type | Verification | A brief description of the sample | PG 64-10 LAS Sample#1 test |
The quantity of what the sample constitutes | 1 | From where was the sample collected | Source |
First name of sampler or witnessed by | B | Last name of sampler or witnessed by | Felder |
Title of sampler | Consultant | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | griffith | Transportation Laboratory (TL) Number | 929978 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 64-10 |
---|---|---|---|
Modified | No | Lot number | Unknown |
Sublot number | Unknown | Tank number | Not set |
Time of sample | Not set | HMA Supplier | Not set |
Certified Asphalt Supplier | Not set | Multigrade | Not set |
Multigrade Type | Not set | Asphalt Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2020-06-25-24
DIME Test ID: 2020-06-25-24-13
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2020-08-24
Test Results
Phase: RTFO residue
Input Type: Measured
Tester's full name: Eva Torres
Date of test: 08/24/2020
Test Plate Diameter: 25 mm
Test Gap: 1 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 10.00 %
Stress Amplitude: 0.252 kPa
Phase Angle (δ) (for the 10 cycles): 88.9 degree
Complex Modulus (G*) (for the 10 measurements): 2.523 kPa
Test Temperature (Specimen 1): 64.0 C
Dynamic Shear, G*/sin(δ): 2.52 kPa
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/24/2020 ✔