Summary for Test 2020-08-10-3-4
Test performed: ASTM F606-14aProject Information
Project Identifiers | Project ID: 77777 DEA: CHEM-STOCK EFIS: CHEM-STOCK |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for Chem Lab stock material. Object Code: 1025. J2 DEA: 912680. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 08/10/2020 | Sample Unique Key | 3 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/19/2020 |
Sample type | Quality Assurance | A brief description of the sample | High Strength Fastener Assemblies |
The quantity of what the sample constitutes | 500 bolts and nuts, 1000 washers | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Craig | Last name of sampler or witnessed by | Hager |
Title of sampler | QA Inspector | Telephone number of sampler | 925-899-1184 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | UIS Lindon UT | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B29-039-20 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | TT0130552 |
---|---|---|---|
Heat Number(s) | bolt 20411200 nut 190002 washer 9418012 | Nut Mfg. Lot Number(s) | 30949-190002 |
Washer Mfg. Lot Number(s) | D7209 | Bolt Specification | A325 |
Bolt Length(s) | 2-1/2" | Nut Specification | A563-DH |
Washer Specification | F436 | Finish | all MG |
Diameter/Size | 5/8" | Bolt Mfg. Lot Number | BM0330 |
Rocap Test Requirement(s) | Yes | Lubricant Requirements(s) | None |
Test Details
DIME Sample ID: 2020-08-10-3
DIME Test ID: 2020-08-10-3-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2020-08-24
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 08/20/2020
UTM: 450kip
Temperature: 72 f
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
---|---|---|---|---|---|---|---|
1 | 1B | 30949-190002 | 36152 | Nut Proof | fsaylor |
General comments (publicly viewable) (Max 1000 characters): Nut Proof
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.
Test was verified on 8/24/2020 ✔