Summary for Test 2020-08-17-6-2

Test performed: ASTM D412-06a-re13

Project Information

Project IdentifiersProject ID: 213762
DEA: 032F3404
EFIS: 0300020616
DIST-CO-RTE-PM03-PLA-49-3.1/7.5
Award Date02/28/2019
Closeout Date05/11/2022
Work DescriptionWIDEN SHOULDERS, ADD RETAINING WALLS, REPLACE MBGR, CURBS & ELECTRICAL
Location DescriptionPLACER COUNTY IN AND NEAR AUBURN FROM 0.1 MILE SOUTH OF ROUTE 49/80 SEPARATION TO 0.1 MILE NORTH OF DRY CREEK ROAD
QA Service Level1 (Verified on 01/08/2019)

Sample Information

Sample Taken Date08/17/2020 Sample Unique Key6
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/18/2020
Sample typeQuality Assurance A brief description of the sampleBearing Pad
The quantity of what the sample constitutes1 From where was the sample collectedManufacturer
First name of sampler or witnessed byIsmail Last name of sampler or witnessed byIBRAHIM
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameScougal Rubber Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM1 - Elastomeric Bearing Pad Mfg. Lot Number(s)19033-1
Material/Compound/Elastomer IDna Samples Representing31
Description (size)1.15"x9"x9" Comments
Description (Number of Shims)2 Type of Bearing PadSteel
Description (Thickness of Shims)14 gage Manufacturer(s)Scougal Rubber
Batch Numberna

Test Details

DIME Sample ID: 2020-08-17-6
DIME Test ID: 2020-08-17-6-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM D412-06a-re13: Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers-Tension
Test Release Date: 2020-08-20

Test Results


Number of specimens tested: 5
Unit of the Ultimate Tensile Values: lbf per sqr in
Input Type: Calculated
Tester's full name: spaine
Date of test: 08/20/2020
UTM: 2kip
Humidity: 50.00 %
Temperature: 72 F
Sample 1 Median Thickness: 0.07
Sample 1 Thickness all Within 0.003 inch?: Yes
Sample 1 Ultimate Tensile: 2434.83 lbf/in^2
Sample 1 Elongation (350% Min): Pass
Sample 2 Median Thickness: 0.07
Sample 2 Thickness all Within 0.003 inch?: Yes
Sample 2 Ultimate Tensile: 1794.92 lbf/in^2
Sample 2 Elongation (350% Min): Pass
Sample 3 Median Thickness: 0.073
Sample 3 Thickness all Within 0.003 inch?: Yes
Sample 3 Ultimate Tensile: 2132.71 lbf/in^2
Sample 3 Elongation (350% Min): Pass
Sample 4 Median Thickness: 0.069
Sample 4 Thickness all Within 0.003 inch?: Yes
Sample 4 Ultimate Tensile: 2585.12 lbf/in^2
Sample 4 Elongation (350% Min): Pass
Sample 5 Median Thickness: 0.071
Sample 5 Thickness all Within 0.003 inch?: Yes
Sample 5 Ultimate Tensile: 2173.63 lbf/in^2
Sample 5 Elongation (350% Min): Pass
Median of the Ultimate Tensile Values: 2173.6 lbf/in^2
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Bluehill Data Point File
Test graph for Sample 3

Source: Bluehill Data Point File
Test graph for Sample 4

Source: Bluehill Data Point File
Test graph for Sample 2

Source: Bluehill Data Point File
Test graph for Sample 5

Source: Bluehill Data Point File
Test graph for Sample 1

Test was verified on 8/20/2020