Summary for Test 2020-08-10-6-1
Test performed: ASTM F606-14aProject Information
Project Identifiers | Project ID: 77777 DEA: CHEM-STOCK EFIS: CHEM-STOCK |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for Chem Lab stock material. Object Code: 1025. J2 DEA: 912680. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 08/10/2020 | Sample Unique Key | 6 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/19/2020 |
Sample type | Quality Assurance | A brief description of the sample | High Strength Fastener Assemblies |
The quantity of what the sample constitutes | 100 bolts and nuts, 200 washers | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Craig | Last name of sampler or witnessed by | Hager |
Title of sampler | QA Inspector | Telephone number of sampler | 925-899-1184 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | UIS Lindon UT | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B29-042-20 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | TT0130559 |
---|---|---|---|
Heat Number(s) | bolt 100790392 nut 188310 washer 175706 | Nut Mfg. Lot Number(s) | 28660-188310 |
Washer Mfg. Lot Number(s) | 308273 | Bolt Specification | A325 |
Bolt Length(s) | 4" | Nut Specification | A563-DH |
Washer Specification | F436 | Finish | MG |
Diameter/Size | 1-1/8" | Bolt Mfg. Lot Number | BM0720 |
Rocap Test Requirement(s) | Yes | Lubricant Requirements(s) | None |
Test Details
DIME Sample ID: 2020-08-10-6
DIME Test ID: 2020-08-10-6-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2020-08-24
Test Results
Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 08/19/2020
UTM: 450kip
Temperature: no data
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 1A | BM0720 | 1.1250 | 104178 | 463.41 | 6.00 | A325 Bolt | fsaylor |
General comments (publicly viewable) (Max 1000 characters): A325 Bolt
Test Graph
Source: Bluehill Data Point FileTest was verified on 8/24/2020 ✔