Summary for Test 2020-07-31-3-14
Test performed: ASTM B499-14Project Information
Project Identifiers | Project ID: 212596 DEA: 100L0204 EFIS: 1013000053 |
---|---|
DIST-CO-RTE-PM | 10-SJ,STA-99-0.0-0.7:24.4-24.8 |
Award Date | 11/30/2018 |
Closeout Date | 07/15/2021 |
Work Description | Partial Bridge Replacement |
Location Description | ON ROUTE 99 IN RIPON AT THE COUNTY LINE OF SAN JOAQUIN COUNTY AND STANISLAUS COUNTY AT THE STANISLAUS RIVER BRIDGES (29-0013L/R). |
QA Service Level | 1 (Verified on 12/19/2018) |
Sample Information
Sample Taken Date | 07/31/2020 | Sample Unique Key | 3 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/06/2020 |
Sample type | Quality Assurance | A brief description of the sample | A325 ROCAP ASSEMBLY |
The quantity of what the sample constitutes | 755 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Mahlon | Last name of sampler or witnessed by | Lindenmuth |
Title of sampler | QA Inspector | Telephone number of sampler | 646-740-3704 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Utah Pacific Bridge and Steel | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | S46-630-20 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | U88982 |
---|---|---|---|
Heat Number(s) | Bolt DL18107414 Nut 75076196 Washer 182006 | Nut Mfg. Lot Number(s) | 30842-S-75076196 |
Washer Mfg. Lot Number(s) | D7353 | Bolt Specification | ASTM A325 |
Bolt Length(s) | 2-1/4" | Nut Specification | ASTM A 563-DH |
Washer Specification | F436 | Finish | HDG |
Diameter/Size | 7/8" | Bolt Mfg. Lot Number | BG1493 |
Rocap Test Requirement(s) | Lubricant Requirements(s) | Lubricated |
Test Details
DIME Sample ID: 2020-07-31-3
DIME Test ID: 2020-07-31-3-14
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Test Release Date: 2020-08-12
Test Results
Input Type: Calculated
Tester's full name: Fred Saylor
Date of test: 08/06/2020
Sample No.: 1B
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: BG1493
Finish Coating: ASTM F2329 - Hot Dip
Product Markings: A325 USA SL
Size: .875 in
Bolt Length: 2.250 in
Measurement Average: 4.74 mils
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/12/2020 ✔