Summary for Test 2020-05-22-27-1
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 212866 DEA: 021H9704 EFIS: 0216000051 |
---|---|
DIST-CO-RTE-PM | 02-TEH-36-12.6/13.1 |
Award Date | 11/25/2019 |
Closeout Date | 10/06/2020 |
Work Description | CURVE REALIGNMENT AND HMA PAVING. |
Location Description | TEHAMA COUNTY ABOUT 16 MILES EAST OF PLATINA FROM 2.3 MILES EAST TO 2.8 MILES EAST OF DRY CREEK BRIDGE |
QA Service Level | 1 (Verified on 01/08/2019) |
Sample Information
Sample Taken Date | 05/22/2020 | Sample Unique Key | 27 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/22/2020 |
Sample type | Verification | A brief description of the sample | 1/2-inch RHMA-G (PG 64-16 CR) with 1.0 Lime |
The quantity of what the sample constitutes | JMF Verification | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Karen | Last name of sampler or witnessed by | Spliethof |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | D78444 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Northstate Asphalt, Redding, CA | Transportation Laboratory (TL) Number | 897706 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
---|---|---|---|
HMA Grading | 1/2 inch | Lot number | |
Sublot number | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2020-05-22-27
DIME Test ID: 2020-05-22-27-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2020-07-24
Test Results
What temperature unit is used?: Fahrenheit
Input Type: Calculated
Tester's full name: Ward Jenkins
Date of test: 07/23/2020
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 1593.2 g
Mass Loss: no data
Correction Factor (Percent by mass of HMA Specimen): 0.25 %
Moisture Content: 0.00 %
Temperature Compensation Factor: no data
Test Temperature: 1000 F
Corrected Asphalt Binder Content: 8.16 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/24/2020 ✔