Summary for Test 2014-11-19-4-1

Test performed: ASTM C39-10
Warning: The test results shown on this page have been superseded and are invalid. This information is for reference only.

Project Information

Project IdentifiersProject ID: 210053
EFIS: 0000000764
DIST-CO-RTE-PM---
Award DateNot set
Closeout DateNot set
Work DescriptionCrush test
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date11/19/2014 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/19/2014
Sample typeDepartment Acceptance A brief description of the samplecylinders
The quantity of what the sample constitutes2 From where was the sample collectedOther
First name of sampler or witnessed byxxxxxxxxxxxxx Last name of sampler or witnessed byxxxxxxx
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility namena Transportation Laboratory (TL) Number87427
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifierUnknown
Structure nameCHP Academy

Material Information

Material TypeConcrete The concrete mix design numberxxxxxxxxxxxxxxxxxxx
The truck number from where the sample was collectedUnknown The batch plant ticket number from where the sample was collectedxxxxxxxxxxxxxxxxxxx
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleUnknown
A detailed description of where the material sample was collectedfrom mix truck Where the material sample would have been placed if not sampledNot set
From Lot No.Not set Bag Lot No.Not set

Test Details

DIME Sample ID: 2014-11-19-4
DIME Test ID: 2014-11-19-4-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2014-12-18

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: SV
Date of test: 12/17/2014
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 5.98 in
Average diameter of cylinder 2: 5.96 in
Maximum load on cylinder 1: 157096 lb
Maximum load on cylinder 2: 157617 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: no data
Age of specimen: 28 days
Cross sectional area of cylinder 1: 28.09 in^2
Cross sectional area of cylinder 2: 27.9 in^2
Compressive strength of cylinder 1: 5592.6 psi
Compressive strength of cylinder 2: 5649.4 psi
Compressive strength (to nearest 10 psi): 5620 psi
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point File
Test graph for Cylinder Code 1 of 2

Source: Partner Data Point File
Test graph for Cylinder Code 2 of 2

Test was verified on 12/18/2014

Warning: The test results shown on this page have been superseded and are invalid. This information is for reference only.