Test performed: ASTM C39-10
Warning: The test results shown on this page have been superseded and are invalid.
This information is for reference only.
Project Information
Project Identifiers | Project ID: 210053 EFIS: 0000000764 |
---|---|
DIST-CO-RTE-PM | --- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Crush test |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 11/19/2014 | Sample Unique Key | 4 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/19/2014 |
Sample type | Department Acceptance | A brief description of the sample | cylinders |
The quantity of what the sample constitutes | 2 | From where was the sample collected | Other |
First name of sampler or witnessed by | xxxxxxxxxxxxx | Last name of sampler or witnessed by | xxxxxxx |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | na | Transportation Laboratory (TL) Number | 87427 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | Unknown | |
Structure name | CHP Academy |
Material Information
Material Type | Concrete | The concrete mix design number | xxxxxxxxxxxxxxxxxxx |
---|---|---|---|
The truck number from where the sample was collected | Unknown | The batch plant ticket number from where the sample was collected | xxxxxxxxxxxxxxxxxxx |
Concrete batch plant | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
A detailed description of where the material sample was collected | from mix truck | Where the material sample would have been placed if not sampled | Not set |
From Lot No. | Not set | Bag Lot No. | Not set |
Test Details
DIME Sample ID: 2014-11-19-4
DIME Test ID: 2014-11-19-4-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2014-12-18
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: SV
Date of test: 12/17/2014
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 5.98 in
Average diameter of cylinder 2: 5.96 in
Maximum load on cylinder 1: 157096 lb
Maximum load on cylinder 2: 157617 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: no data
Age of specimen: 28 days
Cross sectional area of cylinder 1: 28.09 in^2
Cross sectional area of cylinder 2: 27.9 in^2
Compressive strength of cylinder 1: 5592.6 psi
Compressive strength of cylinder 2: 5649.4 psi
Compressive strength (to nearest 10 psi): 5620 psi
General comments (publicly viewable) (Max 1000 characters):