Summary for Test 2020-06-08-38-4
Test performed: AASHTO T269-14Project Information
Project Identifiers | Project ID: 213835 DEA: 051F7404 EFIS: 0514000049 |
---|---|
DIST-CO-RTE-PM | 05-MON-101-R28.0/R30.6 |
Award Date | 04/03/2019 |
Closeout Date | 08/23/2021 |
Work Description | PLACE CONTINUOUSLY REINFORCED CONCRETE PAVEMENT ON EXISTING ROADWAY. |
Location Description | MONTEREY COUNTY NEAR SAN LUCAS FROM 0.1 MILE SOUTH OF PARIS VALLEY ROAD OVERCROSSING TO RANCHO UNDERCROSSING |
QA Service Level | 1 (Verified on 02/18/2019) |
Sample Information
Sample Taken Date | 06/08/2020 | Sample Unique Key | 38 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/19/2020 |
Sample type | Verification | A brief description of the sample | Boxes of HMA-A |
The quantity of what the sample constitutes | One JMF Renewal | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Larry | Last name of sampler or witnessed by | Scott |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | SPM Templeton | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | Unknown |
Sublot number | Unknown | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2020-06-08-38
DIME Test ID: 2020-06-08-38-4
Testing Lab: CT D05 - San Luis Obispo District Laboratory
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Test Release Date: 2020-07-06
Test Results
Number of tests: 3
Is the sample lab compacted or field compacted?:
Input Type: Calculated
Tester's full name: Daniel Gingras
Date of test: 06/30/2020
Percent Air Voids: 0.8 %
Percent Air Voids 2: 1.1 %
Percent Air Voids 3: 1.2 %
Average Percent Air Voids: 1 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/6/2020 ✔