Summary for Test 2020-06-14-4-1

Test performed: AASHTO T240-17
Warning: The test results shown on this page have been superseded and are invalid. This information is for reference only.

Project Information

Project IdentifiersProject ID: 213411
DEA: 030H10U4
EFIS: 0317000246
DIST-CO-RTE-PM03-SAC-5-9.7/24.9
Award Date05/01/2019
Closeout Date02/22/2024
Work DescriptionNot set
Location DescriptionConstruction on state highway in Sacramento County in and near Sacramento from 1.1 miles south of Elk Grove Boulevard to American River Viaduct
QA Service Level1 (Verified on 07/19/2019)

Sample Information

Sample Taken Date06/14/2020 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/17/2020
Sample typeDepartment Acceptance A brief description of the sampleAsphalt Binder
The quantity of what the sample constitutes1 Can, #1 Test From where was the sample collectedSource
First name of sampler or witnessed byM Last name of sampler or witnessed byChitlenden
Title of samplerConsultant Telephone number of sampler
Laboratory sample identificationAB206052 Linked DIME Sample ID
The fabricator/manufacturer/facility nameUnknown Transportation Laboratory (TL) Number716451
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 64-28 M
ModifiedYes Lot numberNot set
Sublot numberNot set Tank numberNot set
Time of sampleNot set HMA SupplierNot set
Certified Asphalt SupplierNot set MultigradeNot set
Multigrade TypeNot set Asphalt Binder Mix NumberNot set

Test Details

DIME Sample ID: 2020-06-14-4
DIME Test ID: 2020-06-14-4-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Test Release Date: 2020-07-01

Test Results


Is mass change based on one or two containers?: One
Input Type: Measured
Tester's full name: Juan Gomez
Date of test: 06/18/2020
Any material loss from containers during heating process/testing?: No
Mass of empty container #1: 174.39 grams
Mass of container #1 before test (m1i): 209.32 grams
Mass of container #1 after test (m1f): 209.06 grams
Average mass change: -0.744 percent
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/1/2020