Summary for Test 2020-05-06-32-1
Test performed: CTM 206-October 2011Project Information
Project Identifiers | Project ID: 214527 DEA: 020H69U4 EFIS: 0218000060 |
---|---|
DIST-CO-RTE-PM | 02-TRI-299-10.9/11.2,42.9/43.3 |
Award Date | 01/03/2020 |
Closeout Date | 10/05/2021 |
Work Description | INSTALL ROCK FALL DRAPERY |
Location Description | TRINITY COUNTY NEAR BURNT RANCH FROM 0.4 MILE EAST OF HENNESSEY ROAD TO 0.3 MILE WEST OF BURNT RANCH SCHOOL ROAD AND FROM 0.5 MILE WEST OF CANYON CREEK BRIDGE TO CANYON CREEK BRIDGE |
QA Service Level | 1 (Verified on 01/22/2020) |
Sample Information
Sample Taken Date | 05/06/2020 | Sample Unique Key | 32 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/11/2020 |
Sample type | Authorization | A brief description of the sample | Rock |
The quantity of what the sample constitutes | Rock | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Brian | Last name of sampler or witnessed by | Alvarez |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | D78428 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | On-Site | Transportation Laboratory (TL) Number | 891128 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | Unknown |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
The plant number | Unknown | A detailed description of where the material sample was collected | Rock Face |
Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | 1-1/2 inch |
The concrete mix design number | Unknown | Lot number | Unknown |
Sublot number | Unknown | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2020-05-06-32
DIME Test ID: 2020-05-06-32-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 206-October 2011: Method of Test for Specific Gravity and Absorption of Coarse Aggregate
Test Release Date: 2020-07-02
Test Results
How will the aggregate be used?: rock slope protection
Input Type: Measured
Tester's full name: TRM
Date of test: 05/14/2020
Mass of Sample + Container (in water): 3046.3 grams
Mass of Container (in water): 0 grams
Mass of Saturated Surface Dry Sample: 4678.8 grams
Mass of Oven Dry Sample: 4658.5 grams
Mass of Sample (in water): 3046.3 grams
Mass of Water Absorbed: 20.3 grams
% Water Absorbed: 0.4 %
Apparent Specific Gravity: 2.89
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/2/2020 ✔