Summary for Test 2020-06-22-1-2

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 214511
DEA: 010E0004
EFIS: 0113000091
DIST-CO-RTE-PM01-HUM-101-84.4/84.8
Award Date01/29/2020
Closeout Date11/22/2023
Work DescriptionBRIDGE RAIL REPLACEMENT.
Location DescriptionHUMBOLDT COUNTY NEAR ARCATA FROM JACOBY CREEK BRIDGE TO GANNON SLOUGH BRIDGE
QA Service Level1 (Verified on 11/13/2019)

Sample Information

Sample Taken Date06/22/2020 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing06/29/2020
Sample typeQuality Assurance A brief description of the sample(4) #6 x2'-4 1/2" Ø
The quantity of what the sample constitutes900 hoops, #6 From where was the sample collectedFabricator
First name of sampler or witnessed byRigoberto Last name of sampler or witnessed byMarin
Title of samplerQA Telephone number of sampler951-500-0685
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameRKR Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL133-108-20 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)158420
Hoop Manufacturer Lot Number(s)Lot 1 Material Standard CodeASTM A706
Material Grade60 Rebar Size#6
Diameter of Hoop2'-4.5" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCascade Steel
Welding CompanyRKR Steel Welding Coating StandardsUncoated
Weld TypeFlash Welded

Test Details

DIME Sample ID: 2020-06-22-1
DIME Test ID: 2020-06-22-1-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2020-06-25

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 06/25/2020
UTM: 400kip
Temperature: 72 f
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
1216/19mm0.4441095.9493400OK Neckingfsaylor

General comments (publicly viewable) (Max 1000 characters): OK Necking
Test Graph
Source: Bluehill Data Point File
Test graph for the Sample

Test was verified on 6/25/2020