Summary for Test 2020-04-21-14-4
Test performed: ASTM C109-16aProject Information
Project Identifiers | Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 04/21/2020 | Sample Unique Key | 14 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/21/2020 |
Sample type | Authorization | A brief description of the sample | Blended cement |
The quantity of what the sample constitutes | 1 Bucket | From where was the sample collected | Source |
First name of sampler or witnessed by | Plant | Last name of sampler or witnessed by | Personnel |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | CM205072 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | LaFarge Holcim | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Cementitious | Brand | LaFarge Holcim |
---|---|---|---|
Mill | Devils Slide | Type of Cementitious Material | Blended Cement |
Test Details
DIME Sample ID: 2020-04-21-14
DIME Test ID: 2020-04-21-14-4
Testing Lab: CT HQ - Sacramento Cement Testing Laboratory
Test Method: ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)
Test Release Date: 2020-07-24
Test Results
Will control cubes be used per ASTM C311?: no
Input Type: Calculated
Tester's full name: Spencer Adams
Date of test: 06/23/2020
Age of specimen: 28 days
The amount of flow : 105 %
The amount of water used : 49.3 %
Compressive strength of 1st specimen : 6479 psi
Compressive strength of 2nd specimen: 5692 psi
Compressive strength of 3rd specimen : 6416 psi
Average Compressive strength (to nearest 10 psi): 6450 psi
General comments (publicly viewable) (Max 1000 characters): 28 day test
Test was verified on 7/24/2020 ✔