Summary for Test 2020-06-12-7-1
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 213835 DEA: 051F7404 EFIS: 0514000049 |
---|---|
DIST-CO-RTE-PM | 05-MON-101-R28.0/R30.6 |
Award Date | 04/03/2019 |
Closeout Date | 08/23/2021 |
Work Description | PLACE CONTINUOUSLY REINFORCED CONCRETE PAVEMENT ON EXISTING ROADWAY. |
Location Description | MONTEREY COUNTY NEAR SAN LUCAS FROM 0.1 MILE SOUTH OF PARIS VALLEY ROAD OVERCROSSING TO RANCHO UNDERCROSSING |
QA Service Level | 1 (Verified on 02/18/2019) |
Sample Information
Sample Taken Date | 06/12/2020 | Sample Unique Key | 7 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/12/2020 |
Sample type | Quality Assurance | A brief description of the sample | 3/4" HMA-A w/RAP & LAS |
The quantity of what the sample constitutes | 1 box | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Brandon | Last name of sampler or witnessed by | Wood |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 20-A-086 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | SPM-Avenal | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | 1 |
Sublot number | 8 | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2020-06-12-7
DIME Test ID: 2020-06-12-7-1
Testing Lab: CT D05 - San Luis Obispo District Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2020-06-17
Test Results
What temperature unit is used?: Fahrenheit
Input Type: Calculated
Tester's full name: Eric Atkins
Date of test: 06/16/2020
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: no data g
Mass Loss: no data
Correction Factor (Percent by mass of HMA Specimen): no data %
Moisture Content: no data %
Temperature Compensation Factor: no data
Test Temperature: no data F
Corrected Asphalt Binder Content: 5.28 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/17/2020 ✔