Summary for Test 2020-06-05-20-3
Test performed: ASTM D624-00-re12Project Information
Project Identifiers | Project ID: 214552 DEA: 044Q1104 EFIS: 0419000347 |
---|---|
DIST-CO-RTE-PM | 04-SM-84-11.7, 11.70 |
Award Date | 05/13/2019 |
Closeout Date | 12/16/2021 |
Work Description | Construct Secant Pile Wall |
Location Description | Near La Honda, at 3.4 miles east of Pescadero Road |
QA Service Level | 1 (Verified on 11/21/2019) |
Sample Information
Sample Taken Date | 06/05/2020 | Sample Unique Key | 20 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/09/2020 |
Sample type | Quality Assurance | A brief description of the sample | Bearing Pad |
The quantity of what the sample constitutes | 34 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Bryan | Last name of sampler or witnessed by | Nagid |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | GRT | Transportation Laboratory (TL) Number | C668877 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | SMTL TM1 - Elastomeric Bearing Pad | Mfg. Lot Number(s) | BP057365C |
---|---|---|---|
Material/Compound/Elastomer ID | NA | Samples Representing | 1 |
Description (size) | 1" x 8" x 12" | Comments | Unknown |
Description (Number of Shims) | NA | Type of Bearing Pad | Plain |
Description (Thickness of Shims) | NA | Manufacturer(s) | GRT |
Batch Number | Unknown |
Test Details
DIME Sample ID: 2020-06-05-20
DIME Test ID: 2020-06-05-20-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM D624-00-re12: Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers
Test Release Date: 2020-06-11
Test Results
Number of specimens tested: 3
Input Type: Measured
Tester's full name: bewing
Date of test: 06/11/2020
Humidity: 50.00 %
Temperature: 72 F
Sample 1 Median Thickness: 0.085
Sample 1 Tear Strength: 202.9
Sample 2 Median Thickness: 0.083
Sample 2 Tear Strength: 207.3
Sample 3 Median Thickness: 0.085
Sample 3 Tear Strength: 205.5
UTM: 2kip
Median of the Tear Strength Values: 205.5 lb/in
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Bluehill Data Point FileTest graph for Sample 3
Source: Bluehill Data Point File
Test graph for Sample 2
Source: Bluehill Data Point File
Test graph for Sample 1
Test was verified on 6/11/2020 ✔