Summary for Test 2020-05-18-12-1
Test performed: ASTM F606-14aProject Information
Project Identifiers | Project ID: 213746 DEA: 080Q75U4 EFIS: 0817000114 |
---|---|
DIST-CO-RTE-PM | 08-SBD,RIV-60-R4.6/R9.9, R0.0/12.2 |
Award Date | 04/18/2019 |
Closeout Date | 06/28/2022 |
Work Description | REPLACEMENT OF TWO OUTSIDE LANES AND CONCRETE SLABS |
Location Description | Not set |
QA Service Level | 1 (Verified on 06/17/2019) |
Sample Information
Sample Taken Date | 05/18/2020 | Sample Unique Key | 12 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/21/2020 |
Sample type | Quality Assurance | A brief description of the sample | F1554 anchor rod |
The quantity of what the sample constitutes | 20 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Jeri | Last name of sampler or witnessed by | Richardson |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | EDSCO | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | 3092321 | Nut Mfg. Lot Number(s) | DDYD, 27217-62144843 |
Washer Mfg. Lot Number(s) | 250650 | Bolt Specification | F1554 Gr55 |
Bolt Length(s) | 52 | Nut Specification | A194 2H |
Washer Specification | F436 | Finish | HDG/Plain |
Diameter/Size | 1.5 | Bolt Mfg. Lot Number | |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2020-05-18-12
DIME Test ID: 2020-05-18-12-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2020-05-28
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 05/26/2020
UTM: 400kip
Temperature: 72 f
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
---|---|---|---|---|---|---|---|
1 | 1 | DDYD | 246624 | Nut Proof | bewing |
General comments (publicly viewable) (Max 1000 characters): Nut Proof
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.
Test was verified on 5/28/2020 ✔