Summary for Test 2020-04-08-9-3
Test performed: AASHTO T335-09r13Project Information
Project Identifiers | Project ID: 213469 DEA: 024C40V4 EFIS: 0218000125 |
---|---|
DIST-CO-RTE-PM | 02-SHA-5-R3.8/R11.7 |
Award Date | 11/06/2018 |
Closeout Date | 08/16/2023 |
Work Description | WIDEN TO 6 LANES, BRIDGE REPLACEMENT AND WIDENING AND ROADWAY REHAB |
Location Description | SHASTA COUNTY IN AND NEAR ANDERSON FROM ROUTE 5/273 SEPARATION TO 0.4 MILE SOUTH OF CHURN CREEK ROAD OVERCROSSING |
QA Service Level | 1 (Verified on 12/31/2018) |
Sample Information
Sample Taken Date | 04/08/2020 | Sample Unique Key | 9 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/08/2020 |
Sample type | Verification | A brief description of the sample | 1/2-inch Type A, Untreated Virgin Aggregate |
The quantity of what the sample constitutes | JMF Renewal | From where was the sample collected | Source |
First name of sampler or witnessed by | Karen | Last name of sampler or witnessed by | Spliethof |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | D78377F | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Fawndale Rock Quarry | Transportation Laboratory (TL) Number | 897564 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-45-0017::FAWNDALE ROCK QUARRY |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
The plant number | Unknown | A detailed description of where the material sample was collected | Lab-Batched from Sized Untreated Aggregate Stockpiles |
Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | 1/2 inch |
The concrete mix design number | JMF 19-12-R1 | Lot number | Unknown |
Sublot number | Unknown | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2020-04-08-9
DIME Test ID: 2020-04-08-9-3
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)
Test Release Date: 2020-05-26
Test Results
Method: 1 - Combined Fracture Determination
Aggregate Size and Fracture Type: Coarse 1 and 2 Faced and Fine 1 Faced
Input Type: Measured
Tester's full name: Colt Sweeny
Date of test: 05/20/2020
Mass of fractured, coarse, 2 faced particles tested: 759.5 g
Mass of questionable, coarse, 2 faced particles tested: 0 g
Mass of unfractured, coarse, 2 faced particles tested: 15.8 g
Mass of fractured, coarse, 1 faced particles tested: 770.7 g
Mass of questionable, coarse, 1 faced particles tested: 0 g
Mass of unfractured, coarse, 1 faced particles tested: 4.6 g
Mass of fractured, fine, 1 faced particles tested: 27 g
Mass of questionable, fine, 1 faced particles tested: 0 g
Mass of unfractured, fine, 1 faced particles tested: 1.7 g
Percentage of questionable, coarse, 2 faced particles tested: 0 %
Percentage of questionable, coarse, 1 faced particles tested: 0 %
Percentage of questionable, fine, 1 faced particles tested: 0 %
Percentage of fractured, coarse, 2 faced particles tested: 98 %
Percentage of fractured, coarse, 1 faced particles tested: 99 %
Percentage of fractured, fine, 1 faced particles tested: 94 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/26/2020 ✔