Summary for Test 2020-04-03-4-1

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 214466
DEA: 081F1414
EFIS: 0815000231
DIST-CO-RTE-PM08-RIV-15-15-54.2/54.3
Award Date01/02/2020
Closeout Date05/26/2022
Work DescriptionSlab & lane replacement with JPCP & precast conc pavement, place HMA.
Location DescriptionRiverside and San Diego County
QA Service Level1 (Verified on 03/20/2020)

Sample Information

Sample Taken Date04/03/2020 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/07/2020
Sample typeVerification A brief description of the sample1/2 RHMA-G-SP
The quantity of what the sample constitutesJMF 2 Bags From where was the sample collectedManufacturer
First name of sampler or witnessed byMike Last name of sampler or witnessed byBergevin
Title of sampler Telephone number of sampler
Laboratory sample identification0187G-20 Linked DIME Sample ID
The fabricator/manufacturer/facility nameCalifornia Commecial Asphalt Lake Elsinore Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-33-0098, 91-33-0011
The fabricator's/manufacturer's product name for the sample1/2 RHMA-G-SP The fabricator/manufacturer designation for the sampleUnknown
The plant number51218180 A detailed description of where the material sample was collectedBelt Cut at California Commercial Asphalt Lake Elsinore Plant
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size1/2 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2020-04-03-4
DIME Test ID: 2020-04-03-4-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2020-05-07

Test Results


What type of gradation is being tested?: HMA Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): Yes
Has the fine aggregate sample been reduced?: No
Input Type: Calculated
Tester's full name: Edmond Jabbour, Larry Diaz
Date of test: 04/09/2020
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 100 %
Cumulative percent passing the 1/2 in. sieve: 98 %
Cumulative percent passing the 3/8 in. sieve: 83 %
Cumulative percent passing the 1/4 in. sieve: 50 %
Cumulative percent passing the #4 sieve: 35 %
Cumulative percent passing the #8 sieve: 21 %
Cumulative percent passing the #16 sieve: 14 %
Cumulative percent passing the #30 sieve: 9 %
Cumulative percent passing the #50 sieve: 7 %
Cumulative percent passing the #100 sieve: 5 %
Cumulative percent passing the #200 sieve: 3.8 %
General comments (publicly viewable) (Max 1000 characters): Virgin Aggregate Gradation

Test was verified on 5/7/2020