Summary for Test 2019-07-01-14-5
Test performed: AASHTO T96-02r10Project Information
Project Identifiers | Project ID: 213826 DEA: 023H1704 EFIS: 0217000066 |
---|---|
DIST-CO-RTE-PM | 02-MOD-299-Var |
Award Date | 02/21/2019 |
Closeout Date | 11/01/2020 |
Work Description | COLD IN-PLACE RECYCLING COVERED WITH HMA, GUARDRAIL, STRIPING. |
Location Description | MODOC COUNTY IN AND NEAR ALTURAS AT VARIOUS LOCATIONS FROM 0.3 MILE EAST OF ROCK CREEK BRIDGE TO PATTERSON STREET |
QA Service Level | 1 (Verified on 01/08/2019) |
Sample Information
Sample Taken Date | 07/01/2019 | Sample Unique Key | 14 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/02/2019 |
Sample type | Verification | A brief description of the sample | Lab-batched, 1/2-inch Type A Aggregate (Untreated Virgin) |
The quantity of what the sample constitutes | JMF | From where was the sample collected | Source |
First name of sampler or witnessed by | Cindy | Last name of sampler or witnessed by | Bryant |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Hogsback | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-25-0029::HOGSBACK |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
The plant number | Unknown | A detailed description of where the material sample was collected | Lab-Batched from Sized Untreated Aggregate Stockpiles |
Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | 1/2 inch |
The concrete mix design number | Unknown | Lot number | Unknown |
Sublot number | Unknown | Aggregate Mix Number | Not set |
Combined Gradation Report Information
Combined Gradation Report Id | Bin Index | Dime Test Id |
---|---|---|
No assigned tests for this sample. |
Test Details
DIME Sample ID: 2019-07-01-14
DIME Test ID: 2019-07-01-14-5
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)
Test Release Date: 2020-04-24
Test Results
Input Type: Calculated
Tester's full name: Dennis Hickey
Date of test: 08/06/2019
Grading designation: C
Percent loss after 100 revolutions: 3 %
Percent loss after 500 revolutions: 14 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/24/2020 ✔