Summary for Test 2020-03-20-18-6
Test performed: AASHTO T304-11Project Information
Project Identifiers | Project ID: 213469 DEA: 024C40V4 EFIS: 0218000125 |
---|---|
DIST-CO-RTE-PM | 02-SHA-5-R3.8/R11.7 |
Award Date | 11/06/2018 |
Closeout Date | 08/16/2023 |
Work Description | WIDEN TO 6 LANES, BRIDGE REPLACEMENT AND WIDENING AND ROADWAY REHAB |
Location Description | SHASTA COUNTY IN AND NEAR ANDERSON FROM ROUTE 5/273 SEPARATION TO 0.4 MILE SOUTH OF CHURN CREEK ROAD OVERCROSSING |
QA Service Level | 1 (Verified on 12/31/2018) |
Sample Information
Sample Taken Date | 03/20/2020 | Sample Unique Key | 18 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/23/2020 |
Sample type | Department Acceptance | A brief description of the sample | 3/4-inch Type A Aggregate (Untreated, Virgin) |
The quantity of what the sample constitutes | 50000 ton | From where was the sample collected | Source |
First name of sampler or witnessed by | Karen | Last name of sampler or witnessed by | Spliethof |
Title of sampler | TET | Telephone number of sampler | |
Laboratory sample identification | D78364F | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Fawndale Rock Quarry | Transportation Laboratory (TL) Number | 897552 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-45-0017::FAWNDALE ROCK QUARRY |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | 19-1001.314 | The fabricator/manufacturer designation for the sample | Unknown |
The plant number | Unknown | A detailed description of where the material sample was collected | Lab-Batched from Sized Untreated Aggregate Stockpiles |
Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | 3/4 inch |
The concrete mix design number | JMF 19-01-XXX1 | Lot number | Unknown |
Sublot number | Unknown | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2020-03-20-18
DIME Test ID: 2020-03-20-18-6
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Test Release Date: 2020-04-21
Test Results
What test method is performed?: Method A
Input Type: Measured
Tester's full name: Dennis Hickey
Date of test: 04/16/2020
Mass of measure: 190.2 grams
Bulk dry specific gravity: 2.702
Mass of sample and measure #1: 327.8 grams
Mass of sample and measure #2: 327.9 grams
Volume of cylinder: 100 mL
Mass of sample #1: 137.6 grams
Mass of sample #2: 137.7 grams
Uncompacted voids #1: 49.1 %
Uncompacted voids #2: 49 %
Average uncompacted voids: 49 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/21/2020 ✔