Summary for Test 2020-03-24-6-18
Test performed: ASTM B499-14Project Information
Project Identifiers | Project ID: 214421 DEA: 01362704 EFIS: 0116000031 |
---|---|
DIST-CO-RTE-PM | 01-MEN-1-62.2/R78.9 |
Award Date | 12/23/2019 |
Closeout Date | 03/09/2021 |
Work Description | HOT MIX ASPHALT OVERLAY. |
Location Description | MENDOCINO COUNTY NEAR FORT BRAGG FROM 0.1 MILE NORTH OF PUDDING CREEK BRIDGE TO 0.6 MILE NORTH OF WAGES CREEK BRIDGE |
QA Service Level | 1 (Verified on 09/19/2019) |
Sample Information
Sample Taken Date | 03/24/2020 | Sample Unique Key | 6 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/10/2020 |
Sample type | Quality Assurance | A brief description of the sample | ASTM A194 2H Heavy Hex Nut |
The quantity of what the sample constitutes | 200 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Mahlon | Last name of sampler or witnessed by | Lindenmuth |
Title of sampler | CT METS QA INSPECTOR | Telephone number of sampler | 646-740-3704 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Ningbo Dongxin Nut Company | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | S46-350-20 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | N/A |
---|---|---|---|
Heat Number(s) | G731102845 | Nut Mfg. Lot Number(s) | 0601DX100-1031-1 |
Washer Mfg. Lot Number(s) | N/A | Bolt Specification | N/A |
Bolt Length(s) | N/A | Nut Specification | ASTM A194 |
Washer Specification | N/A | Finish | ASTM F2329 |
Diameter/Size | 5/8" DIAMETER | Bolt Mfg. Lot Number | N/A |
Rocap Test Requirement(s) | no | Lubricant Requirements(s) | yes |
Test Details
DIME Sample ID: 2020-03-24-6
DIME Test ID: 2020-03-24-6-18
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Test Release Date: 2020-04-15
Test Results
Input Type: Calculated
Tester's full name: Fred Saylor
Date of test: 04/14/2020
Sample No.: 1I
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: 0601DX100-1031-1
Finish Coating: ASTM F2329 - Hot Dip
Product Markings: DX 2H ZN
Size: .625 in
Bolt Length: no data
Measurement Average: 3.79 mils
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/15/2020 ✔