Summary for Test 2020-03-17-5-19

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 210837
DEA: 080J0804
EFIS: 0800000283
COOP: 081625
DIST-CO-RTE-PM08-RIV-15-34.7/51.6
Award Date04/17/2017
Closeout DateNot set
Work Description(Alternative Delivery) DESIGN-BUILD OF THE INTERSTATE 15 EXPRESS LANES PROJECT
Location DescriptionRiverside County and SBD-15-0.0/1.3
QA Service Level1 (Verified on 05/08/2017)

Sample Information

Sample Taken Date03/17/2020 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/01/2020
Sample typeQuality Assurance A brief description of the sampleA325 HDG Rocap Assembiy
The quantity of what the sample constitutes3 From where was the sample collectedDistributor
First name of sampler or witnessed byAndrew Last name of sampler or witnessed byBeck
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameUIS SLSB UNYTITE PRESTIGE Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)TT0126243
Heat Number(s) Nut Mfg. Lot Number(s)29747-S-188648
Washer Mfg. Lot Number(s)D8080 Bolt SpecificationF3125 A325
Bolt Length(s)6 Nut SpecificationA563
Washer SpecificationF436 F959 FinishB695
Diameter/Size1 Bolt Mfg. Lot NumberBM0408
Rocap Test Requirement(s) Lubricant Requirements(s)Blue

Test Details

DIME Sample ID: 2020-03-17-5
DIME Test ID: 2020-03-17-5-19
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2020-04-07

Test Results


Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 04/03/2020
UTM: 450kip
Temperature: no data
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
11BM04081.000088449393.4410.00A325 Boltfsaylor

General comments (publicly viewable) (Max 1000 characters): A325 Bolt
Test Graph
Source: Bluehill Data Point File

Test was verified on 4/7/2020