Summary for Test 2014-09-18-5-4

Test performed: CTM 214-August 2010

Project Information

Project IdentifiersProject ID: 209263
DEA: 080F6604
EFIS: 0800000146
DIST-CO-RTE-PM08-SBD-247-1.8/9.6
Award Date04/28/2014
Closeout Date06/13/2016
Work DescriptionCONSTRUCT SHOULDERS, COLD PLANE AND HMA OVERLAY
Location DescriptionSAN BERNARDINO COUNTY IN AND NEAR YUCCA VALLEY FROM EL CORTEZ ROAD TO HANDLEY ROAD
QA Service Level1 (Verified on 04/16/2014)

Sample Information

Sample Taken Date09/18/2014 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/18/2014
Sample typeAnnual Source Testing A brief description of the sampleThree eighths inch PCC Aggregates
The quantity of what the sample constitutes4 Bags From where was the sample collectedSource
First name of sampler or witnessed byStefan Last name of sampler or witnessed byReder
Title of samplerQuality Assurance Manager Telephone number of samplerUnknown
Laboratory sample identification4264B Linked DIME Sample ID0
The fabricator/manufacturer/facility nameHi Grade 29 Palms Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)SMARA 91 36 0055
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedStockpiles
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size3/8 inch
The concrete mix design number Lot numberNot set
Sublot numberNot set Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2014-09-18-5
DIME Test ID: 2014-09-18-5-4
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 214-August 2010: Method of Test for Soundness of Aggregates by Use of Sodium Sulfate
Test Release Date: 2014-11-19

Test Results


What size aggregate is being tested?: Coarse Aggregate
Input Type: Calculated
Tester's full name: Nemencio Daof
Date of test: 10/17/2014
Percentage Loss of material retained on 2 x 1 ½ in. sieve: no data
Percentage Loss of material retained on 1 ½ x 1 in. sieve: no data
Percentage Loss of material retained on 1 x ¾ in. sieve: no data
Percentage Loss of material retained on ¾ x ½ in. sieve: no data
Percentage Loss of material retained on ½ x ⅜ in. sieve: no data
Percentage Loss of material retained on ⅜ in. x #4 sieve: no data
Percentage Loss of material retained on 2 in. through 1 1/2 in. sieve: no data
Percentage Loss of material retained on 1 in. through 3/4 in. sieve: no data
Percentage Loss of material retained on 3/4 in. through #4 sieve: no data
Weighted Average Percent Loss of Coarse Aggregate: 1.8 %
Batch Soundness Loss of Coarse Aggregate (2 1/2 in maximum): no data
Batch Soundness Loss of Coarse Aggregate (1 1/2 in maximum): no data
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/19/2014