Summary for Test 2020-03-18-9-1
Test performed: ASTM A970-15e1Project Information
Project Identifiers | Project ID: 214190 DEA: 024G41U4 EFIS: 0218000047 |
---|---|
DIST-CO-RTE-PM | 02-SIS,SIS-5-Var |
Award Date | 08/26/2019 |
Closeout Date | 11/24/2021 |
Work Description | REPLACE REINFORCED CONCRETE BRIDGES & CONSTRUCT RETAINING WALL. |
Location Description | SHASTA AND SISKIYOU COUNTIES ABOUT 7 MILES NORTH OF POLLARD FLAT FROM 0.8 MILE SOUTH TO 0.7 MILE NORTH OF SIMS ROAD UNDERCROSSING AND FROM 0.6 MILE SOUTH OF CASTLE CRAGS DRIVE UNDERCROSSING TO 0.2 MILE SOUTH OF SOUTH DUNSMUIR UNDERCROSSING |
QA Service Level | 1 (Verified on 07/09/2019) |
Sample Information
Sample Taken Date | 03/18/2020 | Sample Unique Key | 9 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/24/2020 |
Sample type | Quality Assurance | A brief description of the sample | #10 Rebar with HRC 150 T Head |
The quantity of what the sample constitutes | 16 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Chris | Last name of sampler or witnessed by | Dsouza |
Title of sampler | Telephone number of sampler | 6469423585 | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | HRC Fountain Valley | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | SMTL TM5 - Headed Bars | Production or Authorization Testing | Production Testing |
---|---|---|---|
Rebar Heat Number(s) | 198519 | Head Manufacturer Lot Number(s) | Lot 1 |
Rebar Size | 10 | Headed Bar Model Name | HRC 150 THeads |
Size of Head | Full Size - 9x | Head Connection Type | Friction Weld |
Head Shape | Square | Rebar Manufacturer | Cascade Steel |
Head Manufacturer | HRC | Head Fabricator | HRC |
Material Standard Code | ASTM A615 | Headed Bar Unique ID | Not set |
Test Details
DIME Sample ID: 2020-03-18-9
DIME Test ID: 2020-03-18-9-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2020-03-25
Test Results
Number of Headed Bar Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 03/25/2020
UTM: 400kip
Temperature: 72 f
Num | Lot # | Area (sqin) | Peak Load (lbf) | Tensile Strength (psi) | Comments | Tested By |
---|---|---|---|---|---|---|
1 | 1 | 1.27 | 125290 | 98653 | OK Necking | fsaylor |
General comments (publicly viewable) (Max 1000 characters): OK Necking
Test Graph
Source: Bluehill Data Point FileTest graph for the Sample
Test was verified on 3/25/2020 ✔