Summary for Test 2020-01-27-26-5
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 213596 DEA: 051C8904 EFIS: 0513000009 |
---|---|
DIST-CO-RTE-PM | 05-MON-101-87.3/R91.5 |
Award Date | 12/13/2018 |
Closeout Date | 08/23/2023 |
Work Description | PRECAST CONC PVMT, CRACK AND SEAT PAVEMENT AND RECONSTRUCT RAMPS. |
Location Description | MONTEREY COUNTY IN SALINAS FROM EAST MARKET STREET UNDERCROSSING TO 0.3 MILE SOUTH OF ESPINOSA ROAD |
QA Service Level | 1 (Verified on 01/04/2019) |
Sample Information
Sample Taken Date | 01/27/2020 | Sample Unique Key | 26 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/12/2020 |
Sample type | Verification | A brief description of the sample | 12 boxes of HMA-A |
The quantity of what the sample constitutes | JMF Renewal | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Anthony | Last name of sampler or witnessed by | Romiza |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 20-J-002 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Graniterock Aromas Drum Plant | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 1/2 inch | Lot number | Unknown |
Sublot number | Unknown | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2020-01-27-26
DIME Test ID: 2020-01-27-26-5
Testing Lab: CT D05 - San Luis Obispo District Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2020-03-02
Test Results
What temperature unit is used?: Fahrenheit
Input Type: Measured
Tester's full name: E. Atkins
Date of test: 02/28/2020
Test procedure used?: Method A
Mass of the specimen basket assembly: no data
Mass of the specimen and specimen basket assembly prior to ignition: no data
Mass of HMA Sample prior to ignition: 1618.7 g
Mass Loss: no data
Mass of aggregate remaining after ignition: 1510.3 g
Correction Factor (Percent by mass of HMA Specimen): 1.08 %
Moisture Content: 0.00 %
Temperature Compensation Factor: no data
Test Temperature: 900 F
Corrected Asphalt Binder Content: 5.62 %
General comments (publicly viewable) (Max 1000 characters): Using 482 C
Test was verified on 3/2/2020 ✔