Summary for Test 2020-02-14-6-1

Test performed: ASTM A931-0810

Project Information

Project IdentifiersProject ID: 214276
DEA: 050N2004
EFIS: 0516000016
DIST-CO-RTE-PM05-MON-101-86.0/95.8
Award Date10/16/2019
Closeout Date08/23/2021
Work DescriptionCONSTRUCT TRAFFIC MONITORING STATION SYSTEMS.
Location DescriptionMONTEREY COUNTY IN AND NEAR SALINAS AT VARIOUS LOCATIONS FROM 0.4 MILE NORTH OF AIRPORT BOULEVARD OVERCROSSING TO 0.3 MILE SOUTH OF SAN MIGUEL CANYON OVERCROSSING
QA Service Level1 (Verified on 08/19/2019)

Sample Information

Sample Taken Date02/14/2020 Sample Unique Key6
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/19/2020
Sample typeQuality Assurance A brief description of the sampleAnchor Cable with Swaged Fitting and Stud
The quantity of what the sample constitutes1 From where was the sample collectedManufacturer
First name of sampler or witnessed byAaron Last name of sampler or witnessed byFranklin
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameAssembly Specialty Products Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM10 - Wire Rope Choker Reel Number9237466
Painter Name or IDNA Material SpecificationASTM A931
Size1/2 in Wire ManufacturerWirerope Works
Material Collected to TestNew Reel

Test Details

DIME Sample ID: 2020-02-14-6
DIME Test ID: 2020-02-14-6-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A931-0810: Standard Test Method for Tension Testing of Wire Ropes and Strand (Breaking Force)
Test Release Date: 2020-02-21

Test Results


Input Type: Calculated
Tester's full name:
Date of test: 02/21/2020
Temperature: 72 F
UTM: 400kip
Specimen Identification: Wire Rope
Peak Load: 62473
Operator: NA
Location of Failure: Below Crimp
General comments (publicly viewable) (Max 1000 characters): Ok break
Test Graph
Source: Bluehill Data Point File
Test graph for 2020-02-14-6-1

Test was verified on 2/21/2020